Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2008.tde-22042008-123726
Documento
Autor
Nombre completo
Luiz Fellipe Nakamai
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2008
Director
Tribunal
Campos, Antonio Carlos de (Presidente)
Kiausinis, Vyto
Martins, João Alcino de Andrade
Título en portugués
Calibração do novo dispositivo de ensaio de elevadores dentais para o elevador angulado de Seldin
Palabras clave en portugués
Bioengenharia
Elevador angulado de Seldin
Instrumental cirúrgico-odontológico
Resumen en portugués
Para se entender a biomecânica e implementar avanços nos parâmetros geométricoconstrutivos do elevador angulado de Seldin, foi construído o Novo Dispositivo de Ensaio de Elevadores Dentais (NDEED). Como em um dispositivo de mensuração, foi necessário calibrar-se todo o aparato para garantir que os dados obtidos fossem confiáveis. Para tanto, foram realizados testes estatísticos em relação ao deslocamento angular, torque e deslocamento vertical (LVDT). Para o torque, confrontado com as leituras obtidas, realizou-se o cálculo do índice de correlação linear de Pearson, o qual apresentou valor de 0,99958, indicando alta relação entre os parâmetros avaliados. Em relação ao deslocamento angular e ao deslocamento vertical, o índice de correlação linear de Pearson foi de -0,99995 e 0,99973, respectivamente, indicando alta relação entre as medidas para cada variável. O intervalo de confiança apresentou um erro máximo de ± 0,065 para o torque, ± 1,4 para o deslocamento angular e ± 0,71 para o deslocamento vertical. Com base nos resultados estatísticos, pode-se afirmar que a correlação entre as leituras dos aparelhos e os valores das medidas são extremamente confiáveis, indicando uma ótima relação entre a leitura e a medida. Também foi observado que os intervalos de predição foram pequenos, indicando que o NDEED afere com precisão as medidas em análise. Assim, pode afirmar-se que o Novo Dispositivo de Ensaio de Elevadores Dentais é uma excelente maneira de se aferir as variáveis em estudo.
Título en inglés
Calibration of a new elevator essaying device for the Seldin angulated elevator
Palabras clave en inglés
Bioengineering
Oral surgery instruments
Seldin angulated elevator
Resumen en inglés
In order to understand and optimize the construction of dental elevators, searching for adequate standards, a fully automatic new Elevator Essaying Device has been produced. As in every measurement device, it was a need to calibrate all the apparatus to guarantee that the data obtained was reliable. For this purpose, statistical analysis were used in order to evaluate the angular displacement, torque and vertical displacement. As for the torque, the Pearson's linear correlation index was used, with an obtained value of 0,99958, indicating a high relationship between the evaluated parameters. For the angular displacement and the vertical displacement, the value of the Pearson's linear correlation coefficient was -0,99995 and 0,99973, respectively. The confidence interval showed a maximum error of ± 0,065 for the torque, ±1,4 for the angular displacement and ± 0,71 for the vertical displacement. Based on the obtained statistical data, it is possible to affirm that the correlation between the readings and the measure values are extremely trustworthy. Also, it was observed that the prediction intervals indicated that the new Elevator Essaying device is able to measure the referred variables.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
LuizFelipeNakamai.pdf (2.06 Mbytes)
Fecha de Publicación
2008-06-24
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.