Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2015.tde-18032015-153604
Documento
Autor
Nombre completo
Vanessa Camillo de Almeida
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Pannuti, Claudio Mendes (Presidente)
Casarin, Renato Corrêa Viana
Cavalcanti, Marcelo de Gusmao Paraiso
Título en portugués
Acurácia e precisão de tomografia computadorizada de feixe cônico e de radiografias periapicais na detecção de defeitos ósseos periodontais interproximais em mandíbulas suínas
Palabras clave en portugués
Diagnóstico
Doenças periodontais
Tomografia computadorizada por raios X
Resumen en portugués
As tomografias computadorizadas de feixe cônico (TCFC) vêm ganhando espaço no cenário odontológico devido ao detalhamento das imagens, sem sobreposição de estruturas anatômicas. O objetivo do presente estudo foi comparar a acurácia e a precisão da tomografia computadorizada de feixe cônico e de radiografias periapicais na detecção de defeitos ósseos interproximais artificiais de diferentes tamanhos. Após cálculo amostral, foram adquiridas 20 mandíbulas suínas, nas quais foi empregada cera para simulação de tecido mole e proteção das faces interproximais dos dentes. Das 80 áreas experimentais (entre 1º e 2º pré-molares e entre 2º pré-molar e 1º molar), após aleatorização, foram criadas 60 lesões (20 com exposição ao ácido por 2 horas, 20 com exposição ao ácido por 4 horas e 20 com exposição ao ácido por 6 horas). Em 20 áreas não foram produzidas lesões (controles). As lesões foram criadas com ácido perclórico 70-72%, aplicado com bolinha de algodão. TCFC e radiografias periapicais foram realizadas e depois analisadas por dois radiologistas treinados. A presença de lesões na mandíbula seca foi considerada o padrão-ouro. Foi calculada a sensibilidade, a especificidade e a acurácia da tomografia e da radiografia periapical na detecção das lesões de diferentes tamanhos. A acurácia da TCFC variou de 0,688 a 0,775 e a da radiografia variou de 0,700 a 0,763. Além disso, o tamanho da lesão influenciou no resultado, sendo que lesões de 6h geraram menos resultados falso-negativos do que as lesões de 2h, em ambos os exames. A reprodutibilidade foi aferida pelo coeficiente kappa. A concordância interexaminador variou de ausente a razoável, enquanto a concordância intraexaminador variou de boa a muito boa. Concluímos que não houve diferença com relação à acurácia da TCFC e da radiografia periapical na detecção de defeitos ósseos interproximais artificiais em mandíbulas suínas.
Título en inglés
Accuracy and precision of cone beam computed tomography and periapical radiographs in detecting interproximal alveolar bone lesions in pig mandibles
Palabras clave en inglés
Diagnosis
Periodontal diseases
Tomography
X-ray computed
Resumen en inglés
Cone beam computed tomography (CBCT) has been considered an advance in dentistry imaging due to its high quality tridimensional images. The aim of this study was to evaluate accuracy and precision of CBCT and periapical radiographs in detecting artificial interproximal alveolar bone lesions of different sizes. After sample size calculation, 20 swine mandibles were acquired and had all soft tissue removed. Red wax was used for soft tissue simulation and to protect interproximal aspects of teeth. After randomization, sixty lesions were created (20 with 2 hour acid exposure, 20 with 4 hour acid exposure and 20 with 6 hour acid exposure) and in 20 areas (controls) no lesions were created, totalizing 80 experimental sites. Bone lesions were produced in experimental areas (between 1st and 2nd premolars and between 2nd premolar and 1st molar) with the use of a cotton pellet soaked in perchloric acid 70-72%. CBCT and periapical radiographs were taken and then analyzed by two trained radiologists. The presence of lesions in the dry mandible was considered the gold standard. Sensitivity, specificity and accuracy in detecting different-sized bone lesions were calculated for CBCT and periapical radiography. Accuracy of CBCT ranged from 0,688 a 0,775 and accuracy of periapical radiography ranged from 0,700 a 0,763. The size of lesion influenced results, since 6h-lesions presented less false-negative results than 2h-lesions, in both exams. Reproducibility was measured by kappa coefficient. Interexaminer concordance varied from none to fair, whereas intraexaminer concordance varied from moderate to substantial. Therefore, we concluded that there was no difference between CBCT and periapical radiography accuracy as regards to detection of artificial interproximal bone lesions in swine mandibles.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-04-16
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI