• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.23.2014.tde-12082014-184420
Document
Auteur
Nom complet
Marcelo Sirolli Ferreira
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2014
Directeur
Jury
César Neto, João Batista (Président)
Pimentel, Suzana Peres
Tosta, Mauro Ferreira Martins
Titre en portugais
Influência do método de osteotomia para preparação do leito na reparação óssea ao redor de implantes de titânio: comparação histológica entre instrumento rotatório e ultrassom cirúrgico piezoelétrico
Mots-clés en portugais
Implante dentário
Osseointegração
Osteotomia
Piezocirurgia
Resumé en portugais
O objetivo deste estudo foi avaliar histomorfometricamente a influência da piezocirurgia (PZ) sobre a reparação óssea ao redor de implantes de titânio. Foram utilizados 15 ratos machos Wistar, com aproximadamente 300g, nos quais em uma das patas o leito para instalação de um implante de titânio foi realizado com um motor rotatório convencional (Grupo Controle) e na outra com ultrassom cirúrgico piezoelétrico (Grupo Piezo). Após 30 dias, os animais foram sacrificados para obtenção do material para análise histológica. Foram avaliados os seguintes parâmetros histomorfométricos (em porcentagem), separadamente, para a região cortical e medular: a proporção de tecido mineralizado (PTM) na região adjacente ao implante (500m adjacentes); área de tecido mineralizado (AO) dentro dos limites das roscas do implante; e a extensão de tecido ósseo em contato direto (CD) com a superfície do implante. Os resultados deste estudo mostraram que não foram observadas diferenças para CD na região medular (p>0,05) e para PTM na região cortical (p>0,05). Por outro lado, um maior preenchimento das roscas foi observado quando utilizou-se a PZ tanto na região cortical (71,50 + 6,91 e 78,28 + 4,38; média + dp para os grupos Controle e Piezo; respectivamente p<0,05) quanto na região medular (9,62 + 4,06 e 19,94 + 14,18; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Resultados semelhantes foram observados para o parâmetro PTM na região medular (9,35 + 5,54 e 18,72 + 13,21; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Já a técnica convencional foi superior à PZ em relação a CD na região cortical (80,42 + 10,88 e 70,25 + 16,93; média + dp para os grupos Controle e Piezo; respectivamente p<0,05). Dentro dos limites do presente estudo, pode-se concluir que a piezocirurgia apresenta-se como uma alternativa viável no preparo de leito para instalação de implantes de titânio.
Titre en anglais
Piezosurgery influence in bone healing around titanium dental implants: histological study in rats
Mots-clés en anglais
Dental Implants
Osseointegration
Osteotomy
Piezosurgery
Resumé en anglais
The aim of this study was to investigate the influence of two techniques of dental implant site preparation on bone healing around titanium dental implants. Fifteen male Wistar rats (+ 300g) were used in the study. In each rat tibiae was randomly assigned to receive the implant site preparation with a conventional drilling technique (Control) or with piezoelectric device (Piezo). After thirty days the animals were sacrificed and then the following histomorphometric parameters were evaluated (in percentage) separately to cortical and cancellous regions: Proportion of mineralized tissue (PMT) adjacent to implant threads (500um adjacent); bone area within the threads (BA); and bone-implant contact (BIC). The results demonstrated that there were no differences between the two groups for cancellous BIC (p>0.05) and cortical PTM (p>0.05). Meanwhile, a higher percentage of BA was observed in PIEZO group in the cortical (71,50 + 6,91 and 78,28 + 4,38; mean + stdev for groups Control and Piezo; respectively p<0.05) and cancellous regions (9,62 + 4,06 and 19,94 + 14,18; mean + stdev for groups Control and Piezo; respectively p<0.05). The piezosurgery also showed higher PTM values in the cancellous zone (9,35 + 5,54 and 18,72 + 13,21; mean + stdev for groups Control and Piezo; respectively p<0.05). However, Control presented better results for BIC in cortical region (80,42 + 10,88 and 70,25 + 16,93; mean + stdev for groups CTRL and PIEZO; respectively p<0.05). Within the limits of the present study, it can be concluded that piezosurgery is a feasible alternative in implant site preparation.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2014-09-26
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.