• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.23.2009.tde-24112009-114532
Document
Auteur
Nom complet
Liliani Fernanda Marques Garcia
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2009
Directeur
Jury
Caldeira, Celso Luiz (Président)
Aun, Carmo Antonio
Gavini, Giulio
Titre en portugais
Avaliação da resistência à fratura vertical de dentes tratados endodonticamente com diferentes materiais obturadores
Mots-clés en portugais
Cimentos dentários
Endodontia
Fraturas dos dentes
Materiais obturadores do canal radicular
Resumé en portugais
O presente estudo teve como objetivo avaliar comparativamente in vitro a resistência à fratura radicular de dentes tratados endodonticamente usando diferentes materiais obturadores: AH Plus (Dentsply/De Trey, Alemanha), Real Seal (Sybron Endo, EUA), GuttaFlow (Coltène/Whaledent, Suíça) , ActiV GP (Brasseler, EUA) e Thermafil (Dentsply-Tulsa Dental, EUA). Sessenta e quatro pré-molares inferiores foram divididos em Grupo Controle (n=4), onde as raízes não foram nem instrumentadas nem obturadas e outros 5 grupos de acordo com os materiais obturadores empregados: Grupo AH Plus (n=12); Grupo Real Seal (n=12); Grupo GuttaFlow (n=12); Grupo ActiV GP (n=12); Grupo Thermafil (n=12). As raízes foram instrumentadas com o sistema Protaper Universal (Dentsply-Maillefer, Suíça), e em seguida foram obturadas com os respectivos materiais. Após a obturação, todos os espécimes foram armazenados à 37º C com 100% de umidade por 72 horas e incluídos em resina acrílica. O ligamento periodontal foi simulado com Impregum, que formou uma fina camada entre a raiz e a resina acrílica. Os espécimes foram submetidos ao teste de resistência à fratura em uma máquina de ensaios triaxiais (1,0mm/min). Os valores médios obtidos e o desvio padrão (em Newtons) em ordem decrescente foram: Grupo controle 394,25 ± 56,17 N; Grupo ActiV GP 263 ± 89,32 N; Grupo Thermafil 198,17 ± 61,65 N; Grupo AH Plus 158,08 ± 31,56 N; Grupo Real Seal 154,92 ± 42,64 N e Grupo GuttaFlow 107,92 ± 20,72 N. Os dados foram submetidos aos testes ANOVA e Dunett (5%). Dentre os grupos experimentais, as raízes obturadas com ActiV GP mostraram-se mais resistentes à força vertical aplicada, porém similares aos grupos controle e Thermafil. Os grupos AH Plus, Real Seal e Thermafil mostraram-se similares estatisticamente quanto à resistência à fratura. O grupo GuttaFlow apresentou menores valores médios de resistência à fratura.
Titre en anglais
Vertical fracture resistance of endodontically treated teeth with different root filling materials
Mots-clés en anglais
Dental cements
Endodontics
Root canal filling materials
Tooth fractures
Resumé en anglais
The aim of this study was to evaluate the in vitro vertical fracture resistance of endodontically treated teeth using different root filling materials: AH Plus (Dentsply/De Trey, Alemanha), Real Seal (Sybron Endo, EUA), GuttaFlow (Coltène/Whaledent, Suíça) , ActiV GP (Brasseler, EUA) and Thermafil (Dentsply- Tulsa Dental, EUA). Sixty four single-rooted human lower premolar were assigned into a Control Group (n=4), where the roots were not prepared or filled, and five experimental groups (n=12) according to the root filling materials: Group AH Plus; Group Real Seal; Group GuttaFlow; Group ActiV GP; Group Thermafil. The roots were prepared using Protaper Universal system (Dentsply-Maillefer, Suíça) and filled using one of the root filling materials. Then, the specimens were stored at 37º C at 100% humidity for 72 hours and included in acrylic resin. The periodontal ligament was simulated by the use of Impregum, which made a thin layer between the root and acrylic resin. The specimens were submitted to a vertical fracture resistance using a testing machine triaxiais (1,0mm/min). The values (Newton) and standard deviations obtained were: Control Group 394,25 ± 56,17N; Group ActiV GP 263 ± 89,32N; Group Thermafil 198,17 ± 61,65N; Group AH Plus 158,08 ± 31,56N; Group Real Seal 154,92 ± 42,64N and Group GuttaFlow 107,92 ± 20,72N. The data were submitted to ANOVA e Dunett tests (5%). Among the experimental groups, roots filled with ActiV GP showed the highest values of resistance of load vertical was applied, and were similar to Control Group and Thermafil. AH Plus, Real Seal and Thermafil groups showed statistical similar fracture resistance. GuttaFlow Group showed the lowest values of fracture resistance.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2009-12-22
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.