Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2006.tde-20092006-092828
Documento
Autor
Nombre completo
Carmen Vianna Abrão
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2006
Director
Tribunal
Caldeira, Celso Luiz (Presidente)
Gavini, Giulio
Macedo, Mary Caroline Skelton
Título en portugués
"A oximetria de pulso como recurso auxiliar na determinação da vitalidade pulpar de dentes permanentes traumatizados"
Palabras clave en portugués
Oximetria de puls
Teste da polpa dentária
Traumatismo dentário
Resumen en portugués
A verificação da vitalidade pulpar depende de recursos semiotécnicos específicos, e, entre eles, os mais comumente empregados são os testes térmicos e elétrico. Tais testes apresentam limitações clínicas que interferem na análise e interpretação dos dados obtidos pelos mesmos. Os testes de sensibilidade são estímulos de origem térmica, elétrica ou mecânica aplicáveis ao dente e que são transmitidos às fibras nervosas sensitivas pulpares. Portanto, não leva em consideração a atividade circulatória do tecido pulpar e as condições de oxigenação, que são os reais indicadores da vitalidade do tecido. Nos casos de traumatismos dentários, por diversos fatores, a resposta pulpar se torna ainda mais difícil de obter. Assim, faz-se necessário avaliar o comportamento fisiológico pulpar através de testes denominados fisiométricos, destacando-se nesta área a oximetria de pulso, que é um método não invasivo e objetivo para determinação da saturação de oxigênio e taxa de pulso de um determinado tecido. Este estudo procurou estabelecer parâmetros para a utilização do oxímetro de pulso como teste de vitalidade pulpar, avaliando, comparativamente, os níveis de saturação de oxigênio obtidos do dedo indicador, de dentes controle positivo e de dentes permanentes traumatizados dos mesmos pacientes. Os dentes traumatizados apresentavam resposta negativa ao teste de sensibilidade pulpar com gás refrigerante e ausência de outro sinal ou sintoma indicativo de necrose pulpar. Os resultados mostraram que não houve diferença estatisticamente significante comparando-se as taxas de oxigenação dos dentes traumatizados nos três tempos (inicial, 30 e 60 dias) e que houve correlação entre as taxas de oxigenação do dedo indicador e dos dentes traumatizados e entre os dentes controle e os dentes traumatizados. Comparando-se as leituras obtidas neste estudo pode-se afirmar que taxas de oxigenação obtidas nos dentes traumatizados são confiáveis, permitindo ainda um monitoramento da condição pulpar ao longo do tempo.
Título en inglés
Pulse oximetry as auxiliar test for determination of pulp vitality in traumatized permanent teeth
Palabras clave en inglés
Dental p ulp test
Dental trauma
Pulse oximetry
Resumen en inglés
The evaluation of pulp vitality depends on diagnosis methods. The most widely used are thermal and electric stimulation. However, thermal and electric testing has limitations in providing accurate diagnosis. These tests are subjective and depend upon perceived response of the patient to a stimulus, as well as the interpretation of that response by the dentist. The limitations with present pulp testing methods are that they only indirectly monitor pulp vitality by measuring neural responses and not circulation. For traumatized teeth, the pulp can be affected in a variety of ways as a function of the severity of the injury therefore, that teeth may not respond to vitality test and establishing an accurate and expedient diagnosis is even more complicated. Pulse oximetry is a completely objective test, requiring no sub jective response from the patient and directly measures the blood oxygen levels. This present study purpose was to evaluate the efficiency of pulse oximetry for testing pulp vitality by establishing correlation parameters between blood oxygen levels from the patient’s index finger, positive control teeth and traumatized permanent teeth which do not respond positively to thermal test with refrigerant spray and do not show any other sign or symptom of mortification. The results showed that there was no statistical significance between blood oxygen levels from traumatized teeth at the three different measure times (initial, 30 and 60 days) and there was a correlation between blood oxygen levels from index finger and the traumatized teeth and control teeth and traumatized teeth.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
CarmenViannaAbrao.pdf (608.24 Kbytes)
Fecha de Publicación
2006-10-19
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.