• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2006.tde-20092006-092828
Document
Author
Full name
Carmen Vianna Abrão
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Caldeira, Celso Luiz (President)
Gavini, Giulio
Macedo, Mary Caroline Skelton
Title in Portuguese
"A oximetria de pulso como recurso auxiliar na determinação da vitalidade pulpar de dentes permanentes traumatizados"
Keywords in Portuguese
Oximetria de puls
Teste da polpa dentária
Traumatismo dentário
Abstract in Portuguese
A verificação da vitalidade pulpar depende de recursos semiotécnicos específicos, e, entre eles, os mais comumente empregados são os testes térmicos e elétrico. Tais testes apresentam limitações clínicas que interferem na análise e interpretação dos dados obtidos pelos mesmos. Os testes de sensibilidade são estímulos de origem térmica, elétrica ou mecânica aplicáveis ao dente e que são transmitidos às fibras nervosas sensitivas pulpares. Portanto, não leva em consideração a atividade circulatória do tecido pulpar e as condições de oxigenação, que são os reais indicadores da vitalidade do tecido. Nos casos de traumatismos dentários, por diversos fatores, a resposta pulpar se torna ainda mais difícil de obter. Assim, faz-se necessário avaliar o comportamento fisiológico pulpar através de testes denominados fisiométricos, destacando-se nesta área a oximetria de pulso, que é um método não invasivo e objetivo para determinação da saturação de oxigênio e taxa de pulso de um determinado tecido. Este estudo procurou estabelecer parâmetros para a utilização do oxímetro de pulso como teste de vitalidade pulpar, avaliando, comparativamente, os níveis de saturação de oxigênio obtidos do dedo indicador, de dentes controle positivo e de dentes permanentes traumatizados dos mesmos pacientes. Os dentes traumatizados apresentavam resposta negativa ao teste de sensibilidade pulpar com gás refrigerante e ausência de outro sinal ou sintoma indicativo de necrose pulpar. Os resultados mostraram que não houve diferença estatisticamente significante comparando-se as taxas de oxigenação dos dentes traumatizados nos três tempos (inicial, 30 e 60 dias) e que houve correlação entre as taxas de oxigenação do dedo indicador e dos dentes traumatizados e entre os dentes controle e os dentes traumatizados. Comparando-se as leituras obtidas neste estudo pode-se afirmar que taxas de oxigenação obtidas nos dentes traumatizados são confiáveis, permitindo ainda um monitoramento da condição pulpar ao longo do tempo.
Title in English
Pulse oximetry as auxiliar test for determination of pulp vitality in traumatized permanent teeth
Keywords in English
Dental p ulp test
Dental trauma
Pulse oximetry
Abstract in English
The evaluation of pulp vitality depends on diagnosis methods. The most widely used are thermal and electric stimulation. However, thermal and electric testing has limitations in providing accurate diagnosis. These tests are subjective and depend upon perceived response of the patient to a stimulus, as well as the interpretation of that response by the dentist. The limitations with present pulp testing methods are that they only indirectly monitor pulp vitality by measuring neural responses and not circulation. For traumatized teeth, the pulp can be affected in a variety of ways as a function of the severity of the injury therefore, that teeth may not respond to vitality test and establishing an accurate and expedient diagnosis is even more complicated. Pulse oximetry is a completely objective test, requiring no sub jective response from the patient and directly measures the blood oxygen levels. This present study purpose was to evaluate the efficiency of pulse oximetry for testing pulp vitality by establishing correlation parameters between blood oxygen levels from the patient’s index finger, positive control teeth and traumatized permanent teeth which do not respond positively to thermal test with refrigerant spray and do not show any other sign or symptom of mortification. The results showed that there was no statistical significance between blood oxygen levels from traumatized teeth at the three different measure times (initial, 30 and 60 days) and there was a correlation between blood oxygen levels from index finger and the traumatized teeth and control teeth and traumatized teeth.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
CarmenViannaAbrao.pdf (608.24 Kbytes)
Publishing Date
2006-10-19
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.