Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.23.2008.tde-20012009-161311
Document
Auteur
Nom complet
Isabelle Elias
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2008
Directeur
Jury
Caldeira, Celso Luiz (Président)
Ferrari, Patricia Helena Pereira
Gavini, Giulio
Titre en portugais
Ensaio sobre o uso da termografia infravermelha na avaliação da vitalidade pulpar in vivo
Mots-clés en portugais
Diagnóstico
Endodontia
Termografia
Resumé en portugais
Atualmente, sabe-se que determinar a vitalidade pulpar testando apenas a sua resposta sensorial nervosa, através de testes térmicos ou elétricos, é discutível, pois tais procedimentos não são suficientemente sensíveis para determinar, em definitivo, o real grau de envolvimento pulpar. Além disso, a vitalidade da polpa não depende apenas de seu suprimento nervoso, mas de seu suprimento sanguíneo. Outro fator a considerar com relação ao diagnóstico pulpar, deve-se à possibilidade da ocorrência de respostas pouco confiáveis em pacientes excessivamente ansiosos ao tratamento odontológico, independente do estímulo empregado e da intensidade do teste. O diagnóstico da vitalidade pulpar através de meios de mensuração da temperatura da coroa do dente, como a termografia infravermelha, que avalia a distribuição de temperatura num corpo através da radiação emitida pela sua superfície, surge como possibilidade para superar as desvantagens dos testes de sensibilidade, como a necessidade da estimulação, as variáveis decorrentes da espessura de dentinaesmalte dos dentes, a idade dos pacientes, a condição da estrutura dentária, entre outras. Esta pesquisa verificou a aplicabilidade da imagem infravermelha na análise da queda de temperatura produzida pelo teste térmico com gás refrigerante e a viabilidade como recurso semiotécnico para diagnóstico endodôntico. Para tal, foram analisados quatro dentes portadores de polpa vital e dois dentes tratados endodonticamente. A metodologia utilizada avaliou, através da imagem térmica, a temperatura da superfície coronária submetidos à queda de temperatura, com e sem a utilização do isolamento absoluto. Os resultados não mostraram diferença significante entre os dentes estudados, no que diz respeito à temperatura da superfície coronária e que a utilização do isolamento absoluto também não alterou os resultados. A metodologia proposta neste estudo mostrou-se altamente eficaz para a análise de mudanças térmicas na superfície dentária. No entanto, novos estudos devem ser realizados para que a termografia infravermelha possa se tornar um recurso viável para utilização em Endodontia.
Titre en anglais
The use of infrared thermographic imaging for pulp vitality evaluation in vivo
Mots-clés en anglais
Diagnosis
Endodontic
Thermography
Resumé en anglais
Nowadays, it is known that the determination of the pulp vitality testing only its nerve sensorial response through thermal or electrical tests is discussable because those procedures are not sufficiently sensitive to determine the degree of pulp involvement. Besides the vitality of the pulp does not only depend on its nerve condition, but on its blood supply too. Another factor to consider during the pulp diagnostic, independently of the nature of stimulus or their intensity, is the possibility to occur non reliable responses in excessively anxious patients face to the dentistry treatment. The diagnosis of the pulp vitality by the measurement of the dental crown temperature such as the infrared thermography (which evaluates the temperature distribution in a body through the radiation emitted by its surface) arises as a possibility to overcome the sensitivity tests disadvantages, for example: the stimulation necessity, the variants due to the thickness of the dentin and enamel, the age, the condition of the dental structure and etc. This study evaluated the applicability of the infrared thermography test in the analysis of temperatures decline produced by thermal test using cold spray, and its viability as an aid for the endodontic diagnostic. Using thermal imaging, this methodology analyzed the temperature of the crowns surface of four teeth with vitality and two endodontically treated teeth when submitted to the cold test with and without the use of rubber dam. The results did not show a significant difference between teeth conditions with regard to the crowns surface temperature and the use of rubber dam did not affect these results. The proposed methodology used in this study showed to be highly efficient to analyzing the thermal changes on the dental surface; however new studies must be performed to turn infrared thermography a practicable aid into the endodontic practice.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
IsabelleeLIAS.pdf (658.59 Kbytes)
Date de Publication
2009-03-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.