• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.23.2010.tde-18082010-131343
Document
Auteur
Nom complet
Ceci Nunes Carvalho
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2010
Directeur
Jury
Santos, Marcelo dos (Président)
Akisue, Eduardo
Ferrari, Patricia Helena Pereira
Titre en portugais
Influência do hidróxido de cálcio na resistência de união de cimentos endodônticos resinosos à dentina radicular
Mots-clés en portugais
Cimentos endodônticos
Endodontia
Hidróxido de cálcio
Microscopia eletrônica de varredura
Resistência de união
Resumé en portugais
Avaliou-se a influência do uso do hidróxido de cálcio como medicação intracanal na resistência de união de obturações endodônticas à dentina radicular quando realizadas com o cimento AH Plus ou Epiphany. Raízes palatinas de primeiros molares superiores humanos foram preparadas com sistema rotatório EndoSequence, e divididas em 4 grupos: G1 fatias preenchidas com AH Plus; G2 - fatias preenchidas com Epiphany; G3 - dentes que receberam medicação intracanal com hidróxido de cálcio por 14 dias e posterior preenchimento das fatias com AH Plus; G4 - dentes que receberam medicação intracanal com hidróxido de cálcio por 14 dias e posterior preenchimento das fatias com Epiphany. Para o teste de pushout as raízes foram fixadas, cortadas e delas obtidas secções seriadas das regiões cervical, média e apical. Após a manobra de preenchimento das fatias, essas permaneceram armazenados por 7 dias em câmara a vácuo a 37º C sob condições de umidade ambiental. Decorrido esse período, os dentes foram preparados para o ensaio mecânico. Os corpos-de-prova foram adaptados a um suporte fixado à base da máquina de ensaios mecânicos universal, onde aplicou-se uma carga à velocidade de 0,5 mm/min no sentido ápico-cervical até o completo deslocamento do material obturador. Após a realização dos ensaios, foi feita análise do padrão de fraturas dos corpos de prova utilizando a microscopia eletrônica de varredura. A análise de variância revelou diferença estatisticamente significante entre os grupos (p<0,05). O teste de Tukey identificou que a resistência de união obtida pelos grupos Epiphany e Epiphany + hidróxido de cálcio foi estatisticamente menor do que a dos grupos AH Plus e AH Plus + hidróxido de cálcio; e, a comparação entre grupos mostrou que o grupo AH Plus + hidróxido de cálcio mostrou-se estatisticamente superior ao grupo AH Plus, portanto o hidróxido de cálcio influencia positivamente apenas na adesão do cimento AH Plus.
Titre en anglais
Influence of calcium hydroxide in the bond strength of root canal sealers to dentin: push-out testing
Mots-clés en anglais
Bond strength
Endodontics
Hydroxide calcium
Root canal sealers
Scanning electron microscopy
Resumé en anglais
We evaluated the influence of calcium hydroxide as an intracanal dressing in the bond strength of root canal filling to the root dentin when performed with AH Plus sealer or Epiphany. Palatal roots of maxillary first molars were prepared with rotary system EndoSequence and divided into 4 groups: G1 - slices filled with AH-Plus G2 - slices filled with Epiphany, G3 - teeth that received root canal dressing with calcium hydroxide for 14 days and then filling out the slices with AH-Plus; G4 - teeth that received root canal dressing with calcium hydroxide for 14 days and then filling out the slices with Epiphany. To test push-out the roots were fixed, cut them and obtained serial sections of cervical, middle and apical. After the maneuvers fills the slices, they remain stored for 7 days in a vacuum chamber at 37°C under conditions of environmental humidity. After this period the teeth were prepared for mechanical testing. The samples were adapted to a bracket attached to the base of the testing machine universal where we apply a load at a speed of 0.5 mm/min towards apicocervical to the complete displacement of the filling material. After the testing, analysis was made of the pattern of fractures of the specimens using scanning electron microscopy. Analysis of variance revealed a statistically significant difference between groups (p < 0,05). The Tukey test indicated that the bond strength obtained by the groups Epiphany and Epiphany + Calcium hydroxide was lower than that of groups AH Plus and AH-Plus + Calcium hydroxide; and, the comparison between groups showed that group AH-Plus + Calcium hydroxide was statistically higher than the AH-Plus group, so the Calcium hydroxide has a positive effect only in the adhesion of AH-Plus sealer.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
CeciNunesCarvalho.pdf (3.08 Mbytes)
Date de Publication
2010-08-24
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.