• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2010.tde-18082010-123433
Document
Author
Full name
Laila Gonzales Freire
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2010
Supervisor
Committee
Santos, Marcelo dos (President)
Cunha, Rodrigo Sanches
Gavini, Giulio
Title in Portuguese
Avaliação do preparo de canais radiculares com instrumentos rotatórios torcidos e usinados, por meio de cortes transversais e da microtomografia computadorizada
Keywords in Portuguese
Instrumentação rotatória
Instrumentos endodônticos
Microtomografia computadorizada
Níquel-titânio
Preparo do canal radicular
Abstract in Portuguese
O preparo químico-cirúrgico é uma das etapas mais importantes do tratamento endodôntico, pois promove a desinfecção do sistema de canais radiculares através da limpeza e da modelagem. Realizar o preparo de canais curvos é um grande desafio, devido à ocorrência freqüente de acidentes operatórios como o transporte do canal. A introdução de instrumentos fabricados em ligas de níquel-titânio (NiTi) contribuiu consideravelmente para a melhora na qualidade da instrumentação dos canais. Os diferentes sistemas rotatórios que são apresentados continuamente ao profissional devem ser estudados com detalhes, pois o seu comportamento pode variar de acordo com o desenho de cada instrumento e as suas características de produção. O objetivo deste estudo foi avaliar, ex vivo, a qualidade do preparo de canais curvos realizado pelos sistemas rotatórios Twisted File (TF; Sybron Endo), torcidos, e EndoSequence (ES; Brasseler), usinados, quanto à habilidade em manter o canal centralizado, analisando a extensão e a direção dos eventuais transportes e o índice de centralização do instrumento (IC), por meio de cortes transversais e da microtomografia computadorizada (CT). Trinta molares inferiores foram divididos em dois grupos, e preparados conforme o delineamento de cada método: G1 - Bramante Modificado e G2 - CT. No G1, os dentes foram incluídos em blocos de resina, e seccionados a 2,0, 3,5 e 5,0 mm do ápice radicular. As secções foram fotografadas, e os blocos, remontados, foram submetidos à instrumentação rotatória. No G2, os dentes foram incluídos em material de moldagem e escaneados com um microtomógrafo, antes e após o preparo. As imagens das seções transversais foram reconstruídas e os cortes axiais correspondentes às distâncias de 2,0, 3,5 e 5,0 mm do ápice radicular foram selecionados. Os resultados foram submetidos ao teste estatístico não-paramétrico Mann-Whitney, para comparações duas a duas. Em ambos os grupos, o transporte do canal e o IC para os sistemas TF e ES foram semelhantes, havendo diferença estatística significante apenas no G2, na secção 3,5 mm, quando o sistema TF causou menos transporte do que o sistema ES, obtendo também um melhor IC (p < 0,05). Quando realizada a comparação entre os métodos, independentemente do instrumento utilizado, o transporte do canal foi significantemente menor (0,17 mm) no grupo 2, do que no grupo 1 (0,27 mm) (p < 0,05). A 3,5 e 5,0 mm, o sistema TF promoveu menos transporte no grupo 2 do que no grupo 1 (p < 0,05). Para o sistema ES, diferença estatística foi encontrada a 2,0 mm, aonde o transporte também foi menor no grupo 2 (p < 0,05). Concluiu-se que os sistemas TF e ES se comportaram de modo semelhante quanto ao transporte do canal e ao IC, permitindo o preparo de canais curvos com pouco desvio. Os dois instrumentos apresentaram desvios tanto para o sentido mesial, quanto para o sentido distal. E quando comparados apenas os métodos de avaliação, no método da CT o transporte do canal foi menor do que no método de Bramante Modificado.
Title in English
Evaluation of root canal preparation with rotary instruments twisted and ground by means of cross sections and microcomputed tomography
Keywords in English
Endodontic instruments
Microcomputed tomography
Nickel-titanium
Root canal preparation
Rotary instrumentation
Abstract in English
The chemomechanical preparation is one of the most important phases of endodontic treatment, because it promotes disinfection of the root canal system by cleaning and shaping. The preparation of curved canals is a major challenge due to the frequent occurrence of operative accidents as the canal transportation. The introduction of instruments of nickel-titanium (NiTi) alloy has contributed considerably to the improvement of canal instrumentation quality. The different rotary systems that are continuously presented to dental professionals should be studied in detail, because their mechanical properties can vary according to the design of each instrument and the manufacture characteristics. The aim of this study was to evaluate, ex vivo, the quality of preparation of curved canals and centering ability of the rotary systems Twisted File (TF) (Sybron Endo), twisted, and EndoSequence (ES) (Brasseler), ground, analyzing the extent and direction of any transportation and the centering ratio of instrument, by cross sections and microcomputed tomography (CT). Thirty lower molars were divided into two groups, and prepared according to the design of each method: G1 Bramante Modified and G2 - CT. In G1, the teeth were embedded in resin blocks and sectioned at 2,0, 3,5 and 5,0 mm from the apex. The sections were photographed and the blocks were reassembled and subjected to rotary instrumentation. In G2, the teeth were embedded in an impression material and scanned with a microtomograph, before and after preparation. The images were reconstructed from the cross sections and the axial sections corresponding to distances of 2,0, 3,5 and 5,0 mm from the apex were selected. The results were submitted to statistical nonparametric test Mann-Whitney. In both groups, the canal transportation and IC for TF and ES systems were similar, with statistical difference only for the 3.5 mm section, while TF system caused less canal transportation than ES system, obtaining also better IC (p <0.05). When compared only the methods, regardless of instrument used, the canal transportation was significantly smaller (0.17 mm) in group 2 than in group 1 (0.27 mm) (p <0.05). At 3.5 and 5.0 mm, TF system promoted less transportation in group 2 than in group 1 (p <0.05). For ES system, statistical difference was found at 2.0 mm, where transportation was also lower in group 2 (p <0.05). It was concluded that the systems TF and ES behaved similarly about the canal transportation and the centering ability, allowing the preparation of curved canals with little deviation. The two instruments showed deviations for both the mesial and distal direction. When comparing only the methods of assessment, at CT the canal transportation was lower than in Bramante Modified method.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2010-08-24
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.