• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2013.tde-18022014-193143
Documento
Autor
Nombre completo
Giovana Borba Gazzinelli Costa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Caldeira, Celso Luiz (Presidente)
Gavini, Giulio
Nassri, Maria Renata Giazzi
Título en portugués
Avaliação da eficiência de sistemas rotatórios para desobturação em canais curvos, por meio de tomografia computadorizada por feixe cônico
Palabras clave en portugués
Instrumentos rotatórios
Níquel titânio
Retratamento endodôntico
Tomografia computadorizada de feixe cônico
Resumen en portugués
O presente estudo teve por objetivo avaliar ex vivo a eficiência de sistemas para retratamento (ProTaper Universal Retratamento, Mtwo Retratamento e D-Race), na desobturação de canais mésio vestibulares curvos de molares superiores, por meio de tomografia computadorizada por feixe cônico. Foram utilizados canais mésio vestibulares com curvatura entre 20° e 40°, de 36 molares superiores, preparados com Protaper Universal (até instrumento F2), obturados com cone ProTaper F2 e cimento AH Plus, pela técnica de condensação lateral. Para a desobturação, os dentes foram divididos em grupos (I: ProTaper Universal Retratamento, II: Mtwo Retratamento e III: D-Race). A captura das imagens foi realizada após a obturação e após a desobturação dos canais radiculares, por meio de tomografia computadorizada por feixe cônico de pequeno volume (Prexion 3D XTrillion Inc). As imagens foram segmentadas utilizando o programa InVesalius, para verificar o material obturador remanescente. O tempo para desobturação também foi analisado. De posse dos valores, iniciais e finais, de volume de material obturador e de estrutura dentinária, a proporção dos volumes foi calculada. Para a análise estatística, os resultados foram avaliados pelos testes de ANOVA e de Múltiplas Comparações de Bonferroni. Os grupos ProTaper Universal Retratamento (13,97%) e D-Race (9,87%), apresentaram os menores volumes percentuais médios de material obturador remanescente, não havendo diferença estatística significante entre eles; porém, apresentaram diferença estatística significante (p 0,05) do grupo Mtwo Retratamento (33,88%). Os três sistemas provocaram desgaste semelhante de dentina após a desobturação. O grupo D-Race apresentou menor tempo para desobturação, estatisticamente diferente em relação aos demais sistemas. As características dos sistemas de retratamento podem interferir na eficiência de desobturação quanto ao tempo e volume de material remanescente.
Título en inglés
Evaluation of the efficiency of rotary systems for remove filling materials in curved canals through cone beam computed tomography
Palabras clave en inglés
Cone beam computed tomography
Nickel-titanium
Root canal retreatment
Rotary instruments
Resumen en inglés
The present study aimed to evaluate, ex vivo, the efficiency of systems for retreatment (ProTaper Universal Retreatment, Mtwo Retreatment and D-Race), in removal filling material of curved mesiobuccal canals of maxillary molars, using cone beam computed tomography. Were used mesiobuccal canals with curvature between 20 ° and 40 °, of 36 molars prepared with ProTaper Universal (until instrument F2), filled with cone F2 ProTaper and AH Plus sealer by lateral condensation. For the removal procedure of filling material, the teeth were divided into groups (I: Protaper Universal Retreatment, II: Mtwo Retreatment and III: D-Race). The capture of images was performed after filling and after the removal procedure of root canal through cone beam computed tomography of small volume (Prexion 3D - XTrillion Inc). The images were segmented using the software InVesalius to check the remaining filling material. The time for removal procedure was also analyzed. Possession of values, initial and final, of volume filling material and dentin structure, the ratio of the volumes was calculated. For statistical analysis, the results were evaluated by ANOVA and Bonferroni's Multiple Comparisons. ProTaper Universal Retreatment (13.97 %) and D-Race (9.87 %) groups had the lowest average percent volume remaining filling material, with no statistically significant difference between them, but showed a statistically significant difference (p 0.05) group Mtwo Retreatment (33.88 %). The three systems caused similar wear dentin after removal procedure. The group D-Race had less time for removal procedure, statistically different compared to the other systems. The characteristics of retreatment systems may interfere with the efficiency of removal procedure on the time and volume remaining material.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-03-25
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.