• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2006.tde-22052006-123028
Document
Author
Full name
Clemente da Silva Fernandes
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2006
Supervisor
Committee
Mattos, Beatriz Silva Camara (President)
Saboya, Antonio Carlos Lorenz
Vasconcellos, Ricardo José de Holanda
Title in Portuguese
"Análise das dimensões ósseas peri-orbitárias por meio de tomografia computadorizada visando a colocação de implantes osseointegráveis"
Keywords in Portuguese
Implantes Osseointegráveis
Mensuração Óssea
Peri-órbita
Tomografia Computadorizada
Abstract in Portuguese
A Prótese Buco Maxilo Facial é a especialidade da Odontologia responsável pela confecção de próteses intra e extra-bucais, indicadas quando regiões maxilofaciais foram perdidas. Implantes craniofaciais podem servir como ancoragem para próteses faciais, inclusive as óculo-palpebrais. O presente trabalho teve como propósito avaliar o comprimento e a espessura da estrutura óssea da região periorbitária e realizar a validação do método de mensuração proposto. Foram realizadas mensurações lineares de comprimento e largura das corticais ósseas das regiões peri-orbitárias em tomografias computadorizadas de 30 crânios humanos secos. Dois examinadores realizaram as mensurações, duas vezes cada um, com intervalos de no mínimo 7 dias, em pontos de referência determinados de acordo com as horas de um relógio. A análise estatística revelou que, para a grande maioria das medidas, as variações intra e inter-examinadores não apresentaram diferenças significantes (p<0,05), indicando que o método de mensuração proposto é confiável e válido para a mensuração da região peri-orbitária. Verificou-se que os três pontos de maior comprimento seguiram a mesma seqüência anatômica para as órbitas direita e esquerda, localizando-se no rebordo supra-orbitário e sendo compatíveis com a inserção de implantes osseointegráveis intra-bucais. Os três pontos localizados na parede lateral e na região látero-inferior da órbita apresentaram comprimento compatível com a utilização de implantes osseointegráveis intra-bucais. A parede medial de ambas as órbitas não apresentou comprimento favorável à inserção de implantes intra-bucais ou crânio-faciais. Os pontos de maior largura foram observados no rebordo supra-orbitário e na região látero-inferior de ambas as órbitas, e aqueles de menor largura foram encontrados na região látero-superior de ambas as órbitas.
Title in English
Dimensional analysis of the periorbital regions using computer tomography for osseointegrated implants insertion
Keywords in English
Bone Measurementm
CT Scan
Osseointegrated Implants
Peri-Orbit
Abstract in English
The Maxillofacial Prosthesis is the dental specialty responsible for the confection of extra and intra-oral prosthesis indicated when facial regions have been lost. Craniofacial osseointegrated implants made possible the confection of implantretained facial prosthesis, namely the orbital prosthesis. This work aimed to evaluate the length and the thickness of the bone structure of the periorbital region and to present the validation of the method. Computer tomographies of 30 dry human skulls were made in order to register linear length and width measurements of the periorbital region. Two examiners, two times each one, took the measurements with intervals of at least 7 days between the measurements. Statistics pointed out that, for most instances, the intra and inter-examiners variations were not significant (p<0.05). Therefore, the method proposed is precise and valid for the measurement of the periorbital region. It was verified that the three points with deeper values followed the same anatomical sequence in the supraorbital rim for the right and left orbits, being compatible with the insertion of intraoral osseointegrated implants. The medial wall of both orbits did not present enough length to allow the insertion of intraoral or craniofacial implants. The points of larger width were observed in the supraorbital rim and in the infralateral region of both orbits, and those of smaller width were found in the supralateral region of both orbits.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2006-06-20
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.