• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2001.tde-14102005-122647
Documento
Autor
Nombre completo
Marcelo Ferreira Witzel
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2001
Director
Tribunal
Braga, Roberto Ruggiero (Presidente)
Campos, Tomie Nakakuki de
Pegoraro, Luiz Fernando
Título en portugués
"Influência do modo de ativação do cimento resinoso e de cargas cíclicas imediatas na resistências de união entre porcelana e dentina"
Palabras clave en portugués
Análise por elementos finitos
Compósito
Tensão de contração
Resumen en portugués
O objetivo deste estudo foi verificar a influência das dimensões do corpo-de-prova sobre a tensão de contração de um compósito em sistemas de teste com compliances conhecidos e em um sistema hipotético com compliance zero. A distribuição das tensões foi avaliada através de análise por elementos finitos. Cilindros de vidro com 2, 4 ou 6 mm de diâmetro foram fixados nas garras da máquina de ensaios (Instron 5565). As alturas dos corpos-de-prova foram definidas ajustando-se a distância entre os cilindros (0,5, 1, 2 e 4 mm). Um compósito quimicamente ativado (Bisfil 2B, Bisco) foi aplicado entre os cilindros. A força máxima após 30 min foi dividida pela área da seção transversal do corpo-de-prova para se obter a tensão nominal (MPa). A partir dos valores do módulo de elasticidade do vidro, diâmetro do cilindro e força desenvolvida, o valor da tensão nominal experimental foi corrigida para estimar a tensão que teria sido obtida caso o sistema tivesse compliance igual a zero. Estes valores foram utilizados na análise por elementos finitos. Alturas menores geraram maior tensão nominal apenas nos diâmetros 4 mm e 6 mm. Houve uma correlação linear direta entre tensão e fator-C. Porém, o efeito de borda ficou evidente nas curvas dos dados agrupados por diâmetro. Não houve relação entre tensão nominal e volume de compósito para todo o conjunto de dados. A correção da tensão resultou em valores mais altos e ampliou as diferenças de tensão entre as alturas. A simulação por elementos finitos evidenciou pronunciado efeito de borda em situações de alto confinamento e os valores da tensão máxima de Von Mises foram mais altos do que a tensão nominal 9 corrigida em qualquer condição experimental. Foi possível concluir que as dimensões do espécime influenciaram os valores de tensão nominal. É possível inferir que a eliminação do compliance tornaria esta influência mais evidente. Existe um pronunciado efeito de borda neste tipo de ensaio, principalmente em condições de alto confinamento.
Título en inglés
Composite shrinkage stress as a function of specimen dimensions
Palabras clave en inglés
Composite
Finite element analysis
Shrinkage stress
Resumen en inglés
The objective of the present study was verify the influence of specimen dimensions on polymerization shrinkage stress of a dental composite in testing systems of known compliance and in a hypothetical system with zero compliance. Stress distribution was evaluated using finite element analysis. Glass rods with 2, 4, or 6 mm diameters were attached to a universal testing machine (Instron 5565). Specimen height was defined by adjusting the distance between the rods (0.5, 1, 2 or 4 mm). A self-cure composite (Bisfil 2B, Bisco) was applied between them. Maximum contraction force after 30 min was divided by the cross-sectional area of the specimen in order to obtain nominal stress (MPa). The corrected nominal stress was calculated using the elastic modulus and elongation of the components of the system, together with the force registered during testing. Corrected values were used in the finite element analysis. Shorter specimens generated higher nominal stress only for the 4 mm and 6 mm specimens. There was a direct linear correlation between stress and C-factor. However, the effect of boundary restraints became evident when data were grouped by diameter. No correlation was found between nominal stress and specimen volume. Data correction for compliance amplified the differences in stress produced by different heights. Finite elements analysis revealed an accentuated boundary effect in high confinement groups. Maximum Von Mises stress was higher than corrected nominal stress in all groups. It was concluded that specimen dimensions influenced test results. Eliminating the influence of system compliance made the effect of specimen 11 dimensions on stress more evident. Boundary restraints have a strong influence in test results, mostly in highly confined conditions.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.