• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.23.2004.tde-30082004-143643
Documento
Autor
Nome completo
Felipe Paes Varoli
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2004
Orientador
Banca examinadora
Costa, Claudio (Presidente)
Arita, Emiko Saito
Montebelo Filho, Agenor
Sewell, Cristina Maria Dumit
Tavano, Orivaldo
Título em português
"Estudo comaparativo das densidades radiográficas de diferentes filmes periapicais obtidas por meio da análise computadorizada em valores de alumínio-equivalente"
Palavras-chave em português
Alumínio-equivalente
Densidade radiográfica
Filme radiográfico
Radioproteção
Resumo em português
RESUMO O objetivo deste estudo foi obter as densidades radiográficas de diferentes filmes periapicais por meio de um programa computadorizado que utiliza a imagem equivalente em alumínio (alumínio-equivalente). Avaliaram-se os filmes Agfa Dentus M2 “Comfort", Kodak InSight, Kodak Ektaspeed Plus, Kodak Ultra-speed e Kodak D. Todos foram expostos aos raios X juntamente com um escalímetro de Alumínio, variando-se o tempo de exposição (0,1 a 1 segundo). Após a leitura das densidades radiográficas construiu-se um gráfico para compararmos as propriedades sensitométricas dos filmes. O filmes mais sensíveis foram o Agfa Dentus M2 “Comfort" e o Kodak InSight, e os menos sensíveis o Kodak Ultra-speed e o Kodak D. Os filmes Agfa Dentus M2 “Comfort" e Kodak InSight apresentaram os maiores contrastes. Os resultados obtidos por este método indicam que deve-se utilizar os filmes Agfa Dentus M2 “Comfort" e Kodak InSight para reduzir a dose de radiação recebida pelo paciente.
Título em inglês
Comparison of radiographic densities from different dental intraoral x-ray films by computed analysis into aluminium-equivalent values
Palavras-chave em inglês
Aluminium-equivalent
Radiation protection
Radiographic density
X-ray film
Resumo em inglês
ABSTRACT The aim of this study was to obtain radiographic densities from different dental intraoral x-ray films through a software using aluminium-equivalent image. The densities had been measured in order to compare dental x-ray films in terms of speed, base plus fog, and contrast. Agfa Dentus M2 “Comfort", Kodak InSight, Kodak Ektaspeed Plus, Kodak Ultra-speed and Kodak D-speed films were evaluated. All films were exposed together with aluminium wedge, at times ranging from 0,1-1 second. By plotting a graphic of density against exposure, sensitometric properties were compared. Agfa Dentus M2 “Comfort" and Kodak InSight films obtained the highest film speed; Kodak Ultra-speed and Kodak D-speed films exhibited the lowest sensitivity. Agfa Dentus M2 “Comfort" and Kodak InSight films had presented valuesm to contrast superior to other films. Therefore, Agfa Dentus M2 “Comfort" and Kodak InSight films must be recommended to minimize the radiation dose to the patient.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
TeseToda.PDF (391.65 Kbytes)
Data de Publicação
2004-12-13
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.