Thèse de Doctorat
DOI
https://doi.org/10.11606/T.23.2004.tde-30082004-143643
Document
Auteur
Nom complet
Felipe Paes Varoli
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2004
Directeur
Jury
Costa, Claudio (Président)
Arita, Emiko Saito
Montebelo Filho, Agenor
Sewell, Cristina Maria Dumit
Tavano, Orivaldo
Titre en portugais
"Estudo comaparativo das densidades radiográficas de diferentes filmes periapicais obtidas por meio da análise computadorizada em valores de alumínio-equivalente"
Mots-clés en portugais
Alumínio-equivalente
Densidade radiográfica
Filme radiográfico
Radioproteção
Resumé en portugais
RESUMO O objetivo deste estudo foi obter as densidades radiográficas de diferentes filmes periapicais por meio de um programa computadorizado que utiliza a imagem equivalente em alumínio (alumínio-equivalente). Avaliaram-se os filmes Agfa Dentus M2 “Comfort", Kodak InSight, Kodak Ektaspeed Plus, Kodak Ultra-speed e Kodak D. Todos foram expostos aos raios X juntamente com um escalímetro de Alumínio, variando-se o tempo de exposição (0,1 a 1 segundo). Após a leitura das densidades radiográficas construiu-se um gráfico para compararmos as propriedades sensitométricas dos filmes. O filmes mais sensíveis foram o Agfa Dentus M2 “Comfort" e o Kodak InSight, e os menos sensíveis o Kodak Ultra-speed e o Kodak D. Os filmes Agfa Dentus M2 “Comfort" e Kodak InSight apresentaram os maiores contrastes. Os resultados obtidos por este método indicam que deve-se utilizar os filmes Agfa Dentus M2 “Comfort" e Kodak InSight para reduzir a dose de radiação recebida pelo paciente.
Titre en anglais
Comparison of radiographic densities from different dental intraoral x-ray films by computed analysis into aluminium-equivalent values
Mots-clés en anglais
Aluminium-equivalent
Radiation protection
Radiographic density
X-ray film
Resumé en anglais
ABSTRACT The aim of this study was to obtain radiographic densities from different dental intraoral x-ray films through a software using aluminium-equivalent image. The densities had been measured in order to compare dental x-ray films in terms of speed, base plus fog, and contrast. Agfa Dentus M2 “Comfort", Kodak InSight, Kodak Ektaspeed Plus, Kodak Ultra-speed and Kodak D-speed films were evaluated. All films were exposed together with aluminium wedge, at times ranging from 0,1-1 second. By plotting a graphic of density against exposure, sensitometric properties were compared. Agfa Dentus M2 “Comfort" and Kodak InSight films obtained the highest film speed; Kodak Ultra-speed and Kodak D-speed films exhibited the lowest sensitivity. Agfa Dentus M2 “Comfort" and Kodak InSight films had presented valuesm to contrast superior to other films. Therefore, Agfa Dentus M2 “Comfort" and Kodak InSight films must be recommended to minimize the radiation dose to the patient.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
TeseToda.PDF (391.65 Kbytes)
Date de Publication
2004-12-13
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.