• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.23.2016.tde-25022016-164732
Document
Auteur
Nom complet
Gilberto Araújo Noro Filho
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2015
Directeur
Jury
Costa, Claudio (Président)
Arita, Emiko Saito
Giovanni, Elcio Magdalena
Macedo, Mary Caroline Skelton
Spin Neto, Rubens
Titre en portugais
Efeito do artefato de "beam hardening" na capacidade de identificação das alterações periodontais e peri-implantares
Mots-clés en portugais
Artefatos
Implante dentário
OsiriX
Tomografia Computadorizada de Feixe Cônico
Resumé en portugais
Artefatos ocorrem principalmente, próximos de estruturas de alta densidade como o metal, sendo que essa alteração pode interferir na interpretação das imagens e no diagnóstico. O intuito do presente estudo é avaliar o nível ósseo ao redor de dentes e implantes por meio de dois programas diferentes e a qualidade da imagem na presença de artefatos metálicos. Foram avaliadas imagens de arquivo obtidas através do TCFC Gendex(TM) GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). Os software utilizados foram o Xelis Dental (InfinnitHealthcare, South Korea) e o OsiriX MD (Pixmeo, Geneva, Switzerland) em cortes tomográficos transaxiais de 2 mm. Foram avaliadas 145 imagens de TCFC, sendo incluídos no estudo 35 exames (as idades variaram de 35 a 83 anos), representando um total de 30 Dentes e 30 Implantes, sendo que houve uma distribuição harmônica entre os grupos em relação ao gênero e idade. Três avaliadores treinados realizaram as observações das imagens separadamente em dois períodos distintos e a qualidade da imagem foi classificada em severa, forte, moderada e mínima. Na avaliação da qualidade de imagem os implantes apresentaram uma prevalência maior de artefatos severo e forte. No entanto, as avaliações dos implantes apresentaram uma maior consistência intra-observador, demonstrando, portanto, uma maior dificuldade na classificação dos dentes. Além disso, na avaliação conjunta de dentes e implantes a consistência global dos observadores aumentou. O software OsiriX apresentou desempenho superior nas medidas lineares dos dentes e implantes na avaliação intra-examinador. Embora nenhuma das correlações intraclasse avaliadas tenha sido excelente, a grande maioria foi satisfatória, com valores entre 0,4 e 0,7. Podemos concluir que a presença de artefatos metálicos limita a qualidade da imagem do nível ósseo ao redor dos dentes e implantes, assim como o programa OsiriX apresentou resultados nitidamente superiores na avaliação das medidas lineares.
Titre en anglais
"Beam Hardening" artefact effect in identifying capacity of periodontal and peri-implant changes
Mots-clés en anglais
Artifacts
Cone-beam computed tomography
Dental implant
OsiriX
Resumé en anglais
Artifacts occur mainly near high-density structures, such as metal, this alteration may affect images interpretation and diagnosis. The aim of this study is to evaluate the bone level around teeth and implants through two different software and image quality in presence of metal artefacts. Archival images obtained were evaluated by CBCT Gendex(TM)GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). The software used was Xelis Dental (InfinnitHealthcare, South Korea) and OsiriX MD (Pixmeo, Geneva, Switzerland) in transaxial tomographic slices of 2 mm. We evaluated 145 CBCT images and included in the study 35 exams (ages ranged from 35 to 83 years-old), representing a total of 30 teeth and 30 implants, there was a harmonic distribution between groups in relation gender and age. Three trained examiners made observations of images separately in two distinct periods and the image quality evaluation was classified in severe, strong, moderate and minimal. Evaluation of implants image quality presented a higher prevalence of severe and strong artifacts. However, implants evaluation presented a higher intra-observer consistency, therefore teeth assessment presents a greater difficulty. In addition, joint assessment of teeth and implants increased global consistency of observers. OsiriX software outperformed intra-examiner linear measurements of teeth and implants. Although none of the intraclass correlations evaluated has been excellent, vast majority was satisfactory, with values between 0.4 and 0.7. We conclude that presence of metal artifacts limits the image quality of bone level around teeth and implants as well as software OsiriX presented significantly better results in the evaluation of linear measurements.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2016-03-07
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.