Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2016.tde-25022016-164732
Documento
Autor
Nombre completo
Gilberto Araújo Noro Filho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Costa, Claudio (Presidente)
Arita, Emiko Saito
Giovanni, Elcio Magdalena
Macedo, Mary Caroline Skelton
Spin Neto, Rubens
Título en portugués
Efeito do artefato de "beam hardening" na capacidade de identificação das alterações periodontais e peri-implantares
Palabras clave en portugués
Artefatos
Implante dentário
OsiriX
Tomografia Computadorizada de Feixe Cônico
Resumen en portugués
Artefatos ocorrem principalmente, próximos de estruturas de alta densidade como o metal, sendo que essa alteração pode interferir na interpretação das imagens e no diagnóstico. O intuito do presente estudo é avaliar o nível ósseo ao redor de dentes e implantes por meio de dois programas diferentes e a qualidade da imagem na presença de artefatos metálicos. Foram avaliadas imagens de arquivo obtidas através do TCFC Gendex(TM) GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). Os software utilizados foram o Xelis Dental (InfinnitHealthcare, South Korea) e o OsiriX MD (Pixmeo, Geneva, Switzerland) em cortes tomográficos transaxiais de 2 mm. Foram avaliadas 145 imagens de TCFC, sendo incluídos no estudo 35 exames (as idades variaram de 35 a 83 anos), representando um total de 30 Dentes e 30 Implantes, sendo que houve uma distribuição harmônica entre os grupos em relação ao gênero e idade. Três avaliadores treinados realizaram as observações das imagens separadamente em dois períodos distintos e a qualidade da imagem foi classificada em severa, forte, moderada e mínima. Na avaliação da qualidade de imagem os implantes apresentaram uma prevalência maior de artefatos severo e forte. No entanto, as avaliações dos implantes apresentaram uma maior consistência intra-observador, demonstrando, portanto, uma maior dificuldade na classificação dos dentes. Além disso, na avaliação conjunta de dentes e implantes a consistência global dos observadores aumentou. O software OsiriX apresentou desempenho superior nas medidas lineares dos dentes e implantes na avaliação intra-examinador. Embora nenhuma das correlações intraclasse avaliadas tenha sido excelente, a grande maioria foi satisfatória, com valores entre 0,4 e 0,7. Podemos concluir que a presença de artefatos metálicos limita a qualidade da imagem do nível ósseo ao redor dos dentes e implantes, assim como o programa OsiriX apresentou resultados nitidamente superiores na avaliação das medidas lineares.
Título en inglés
"Beam Hardening" artefact effect in identifying capacity of periodontal and peri-implant changes
Palabras clave en inglés
Artifacts
Cone-beam computed tomography
Dental implant
OsiriX
Resumen en inglés
Artifacts occur mainly near high-density structures, such as metal, this alteration may affect images interpretation and diagnosis. The aim of this study is to evaluate the bone level around teeth and implants through two different software and image quality in presence of metal artefacts. Archival images obtained were evaluated by CBCT Gendex(TM)GXCB500 (Gendex Dental Systems, Des Plaines, IL, USA). The software used was Xelis Dental (InfinnitHealthcare, South Korea) and OsiriX MD (Pixmeo, Geneva, Switzerland) in transaxial tomographic slices of 2 mm. We evaluated 145 CBCT images and included in the study 35 exams (ages ranged from 35 to 83 years-old), representing a total of 30 teeth and 30 implants, there was a harmonic distribution between groups in relation gender and age. Three trained examiners made observations of images separately in two distinct periods and the image quality evaluation was classified in severe, strong, moderate and minimal. Evaluation of implants image quality presented a higher prevalence of severe and strong artifacts. However, implants evaluation presented a higher intra-observer consistency, therefore teeth assessment presents a greater difficulty. In addition, joint assessment of teeth and implants increased global consistency of observers. OsiriX software outperformed intra-examiner linear measurements of teeth and implants. Although none of the intraclass correlations evaluated has been excellent, vast majority was satisfactory, with values between 0.4 and 0.7. We conclude that presence of metal artifacts limits the image quality of bone level around teeth and implants as well as software OsiriX presented significantly better results in the evaluation of linear measurements.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2016-03-07
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.