• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.23.2006.tde-22032007-120737
Documento
Autor
Nome completo
Mario Sergio Saddy
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2006
Orientador
Banca examinadora
Chilvarquer, Israel (Presidente)
Morea, Camillo
Pereira, Marlene Fenyo Soeiro de Matos
Rodriguez, Gladys Cristina Dominguez
Vita, Renato
Título em português
"Estudo comparativo entre a tomografia computadorizada e a tomografia volumétrica na confecção de modelos de prototipagem"
Palavras-chave em português
Prototipagem
Tomografia computadorizada
Tomografia volumétrica
Resumo em português
O objetivo neste estudo foi comparar modelos de prototipagem, originados a partir de dados obtidos em exames de tomografia volumétrica (TV) e tomografia computadorizada (TC), a fim de verificar a precisão de reprodutibilidade destas tecnologias. Uma mandíbula seca foi submetida aos exames de TV (NewTom 9000? QR, Itália) e TC (Select SP-Elscint, Israel). Os dados obtidos nos exames foram manipulados em dois sistemas de tratamento de imagem, o 3D- Analyze (Mayo Clinic, E.U.A.) e o InVesalius (CenPRA, Brasil) e confeccionados protótipos, em duas diferentes tecnologias (SLS - sinterização seletiva a laser e 3DP - impressão tridimensional). A mandíbula seca (padrão ouro) e os oito conjuntos de protótipos gerados, sendo I-TC-Analyze?3DP; II-TC-Invesalius?3DP; III-TC-Analyze?SLS; IVTC- Invesalius-SLS; V-TV-Analyze?3DP; VI-TV-Invesalius?3DP; VIII-TV-Analyze? SLS; VIII-TV-Invesalius-SLS, foram submetidos a processos de engenharia reversa com a finalidade de digitalizar as superfícies dos objetos para uma comparação de cada modelo de prototipagem produzido com o padrão ouro, com precisão de 0,001mm. Os desvios de até 1mm e até 2mm foram calculados, comparados e analisados estatisticamente os erros percentuais. Os modelos de prototipagem rápida originados por meio da obtenção de dados de exames de tomografia computadorizada são mais precisos que os modelos de prototipagem originados por meio de dados de exames de tomografia volumétrica.
Título em inglês
Comparison of cone beam computerized tomography and multislice computerized tomography for building rapid prototyping models
Palavras-chave em inglês
Computerized Tomography
Cone Beam Computerized Tomography
Prototyping
Resumo em inglês
The purpose of this study is to compare rapid prototyping models created from cone beam computerized tomography (CBCT) and multislice computerized tomography (CT) data, in order to verify the accuracy of these technologies. A dry skull mandible was submitted in a CBCT (NewTom ? QR, Italy) and CT (Select SP-Elscint, Israel) exams. The tomographies data were processed by two different Medical Image processing systems, 3D-Analyze (Mayo Clinic, U.S.A.) and InVesalius (CenPRA, Brazil). Rapid prototypes models were built in two different rapid prototyping technologies, 3D Printer (3DP) and Selective Laser Sintering (SLS). The dry skull mandible (gold standard) and the eight prototypes, as follows; I-CT-Analyze?3DP; IICT- Invesalius?3DP; III-CT-Analyze?SLS; IV-CT-Invesalius-SLS; V-CBCT-Analyze? 3DP; VI-CBCT-Invesalius?3DP; VIII-CBCT-Analyze?SLS; VIII-CBCT-Invesalius-SLS, were submitted to a reverse engineering process aimed to digitalize the surfaces of the objects to compare each rapid prototype model with the gold standard with a precision of 0.001mm. Percentage deviations errors until 1.0mm and 2.0mm were calculated, compared and statistically analyzed. The prototyped models obtained with multislice computerized tomography data shows more accuracy than those obtained with data from cone beam computerized tomography.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Tese_Saddy.pdf (2.08 Mbytes)
Data de Publicação
2007-07-30
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.