• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2013.tde-18102013-185639
Documento
Autor
Nombre completo
Renata de Saldanha da Gama
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2013
Director
Tribunal
Costa, Claudio (Presidente)
Arita, Emiko Saito
Rosa, Véra Lúcia Mestre
Título en portugués
Acurácia de medidas lineares em região posterior de mandíbulas obtidas por tomografia computadorizada de feixe cônico através de diferentes protocolos de aquisição
Palabras clave en portugués
Acurácia
Tomografia
Tomografia Computadorizada de Feixe Cônico
Resumen en portugués
A utilização da tomografia computadorizada de feixe cônico (TCFC) permite avaliar a altura e espessura do osso remanescente para a instalação de implantes. As mandíbulas atrésicas necessitam de maior grau de detalhamento para obtenção de medidas. A autora, no presente estudo, avaliou a influência do tamanho dos voxels (0,125mm e 0,25mm) nas medidas de altura e espessura em 10 mandíbulas desdentadas e atrésicas. Para determinação dos cortes tomográficos no estudo foram utilizados fios metáticos nas regiões posteriores. Após o exame as mandíbulas foram seccionadas e as medidas diretas de altura e espessura foram obtidas pelo uso de paquímetro digital. Os resultados pelo teste ICC demonstraram não haver diferenças estatisticamente significantes entre as medidas realizadas pelos dois examinadores com paquímetro e as tomografias. Concluiu-se que a TCFC é confiável para realização de medidas na mandíbula e que o tamanho do voxel não interferiu no planejamento cirúrgico.
Título en inglés
Accuracy of linear measurements in posterior region of mandible obtained by cone beam computed tomography through different acquisition protocols
Palabras clave en inglés
Accuracy
Cone Beam CT
Tomography
Resumen en inglés
The use of cone beam computed tomography (CBCT) allows to evaluate the height and thickness of the remaining bone for implant placement. The atresic mandible requires higher level of detail for obtaining measurements. The author in the present study evaluates the influence of the voxel size (0.125 mm and 0.25 mm) in thickness and height measurements using 10 edentulous dry mandibles. For determination of the tomographic study were used metallic wires in the posterior regions. After examining, the mandibles were sectioned and direct measures of height and thickness were obtained through digital caliper. The results by ICC test showed no statistically significant differences between the measurements with caliper and tomograms made by two examiners. It was concluded that CBCT is trusted to carry out measurements in mandible and the voxel size did not affect the surgical planning.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2014-01-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.