• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.23.2018.tde-15082018-094151
Documento
Autor
Nome completo
Renan Lucio Berbel da Silva
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Paulo, 2018
Orientador
Banca examinadora
Chilvarquer, Israel (Presidente)
Hayek, Jorge Elie
Luz, Joao Gualberto de Cerqueira
Pereira, Marlene Fenyo Soeiro de Matos
Título em português
Avaliação da densidade ótica peri-implantar cervical em controle longitudinal de implantes na região anterior de maxila
Palavras-chave em português
Densidade ótica
Osteointegração
Subtração radiográfica
Resumo em português
As complicações peri-implantares, posteriormente a colocação do implante em função, são frequentes e sua identificação precoce pode significar uma terapêutica adequada e consequentemente garantir o sucesso do terapêutica. A proposta neste trabalho foi avaliar longitudinalmente a densidade ótica do osso alveolar peri-implantar na região cervical, analisada, por meio da técnica de subtração radiográfica de um acervo de radiografias digitais adquiridas de pacientes previamente reabilitados com trinta e sete implantes osteointegrados imediatos na região anterior da maxila. Os controles radiográficos foram realizados em cinco momentos: na instalação das próteses, após 15,90,180 e 360 dias, e as radiografias intrabucais foram obtidas pela técnica do paralelismo de cilindro longo, com posicionadores do tipo Hanshin individualizados de forma a garantir a padronização das imagens. As imagens digitais obtidas foram alinhadas e equalizadas e por fim submetidas ao procedimento de subtração radiográfica. Os resultados indicaram que a metodologia de subtração radiográfica é válida para a avaliação da perda óssea peri-implantar, assim como demonstra a literatura. No entanto, a reprodução das angulações verticais e horizontais, apresentam-se como críticas na avaliação da densidade óptica da crista óssea e demandam grande habilidade do operador para a correta aplicação. Por meio dessa técnica, conseguimos avaliar de forma quantitativa e qualitativa as alterações na faces proximais nas imagens radiográficas do acervo analisado. A subtração radiográfica, por meio da ferramenta de histograma, permitiu quantificar de forma objetiva as diferenças encontradas nas análises.
Título em inglês
Evaluation of cervical peri-implant optic density in longitudinal control of implants in the anterior maxilla region
Palavras-chave em inglês
Optical density
Osseointegration
Radiographic subtraction
Resumo em inglês
The peri-implant complications, in addition to implant placement in function, are frequent and their early identification could mean a therapy appropriately and consequently guarantee the success of the treatment. The aim of this research was to longitudinally evaluate of the optical density of the peri-implant alveolar bone at the cervical region, analyzed by means of the radiographic subtraction technique, a collection of digital radiographs acquired from patients previously rehabilitated with thirty seven osseointegrated implants. The radiographic controls performed in five moments, at the installation of the prostheses, after 15,90,180 and 360 days, and the intraoral radiographs were obtained by parallelism technique, with Hanshin-type positioners individualized in order to guarantee the standardization of the images. The obtained digital images were aligned and equalized and finally submitted to radiographic subtraction procedure. The results indicated that the methodology of radiographic subtraction is valid for an evaluation of the peri-implant bone loss, as well as to demonstrated at the literature. However, the reproduction of the vertical and horizontal angles, are presented as critical in the evaluation of the optical density, and demand a great ability of the operator for a correct application. Through the technique we obtained a quantitative and qualitative evaluation in the area of proximal images in the radiographic images of the analyzed data. The histogram tool applied on the radiographic subtraction images allowed to quantify objectively as the differences found in the analyzes.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2018-08-17
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.