• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2018.tde-05112018-123430
Documento
Autor
Nombre completo
Jun Ho Kim
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2018
Director
Tribunal
Arita, Emiko Saito (Presidente)
Côrtes, Arthur Rodriguez Gonzalez
Prado, Marina Cleia Palo
Raitz, Ricardo
Título en portugués
Comparação da precisão e acurácia de medidas lineares com diferentes protocolos de tomografia computadorizada por feixe cônico
Palabras clave en portugués
Artefatos
Defeitos ósseos periimplantares
Tomografia computadorizada por feixe cônico
Resumen en portugués
Uma das complicações mais importantes relacionadas com o tratamento de implante dentário é a peri-implantite. Devido a limitação pela sobreposição de estruturas da técnica periapical, nos casos da perda óssea peri-implantar nas faces vestibulares e linguais ou palatais necessita-se de um exame capaz de prover imagens em 3 dimensões para o correto diagnóstico, sendo as imagens de tomografia computadorizada por feixe cônico (TCFC) as mais indicadas. O objetivo deste estudo foi avaliar a acurácia, especificidade, sensibilidade, concordância inter e intraobservadores e determinar a influência dos artefatos na detecção dos defeitos ósseos peri-implantares simulados em mandíbulas humanas edêndulas secas. Foram utilizados dois aparelhos de TCFC com diferentes protocolos de aquisição: i-CAT Gendex CB-500(120kVp, 5mA) e ORTHOPANTOMOGRAPH OP300(90kVp, 6.3mA). Foram instalados 24 implantes dentários cilíndricos e executados dezesseis defeitos somente nas faces vestibulares, com os comprimentos que variaram de 0,5mm a 15mm. Somente cortes sagitais foram utilizados para avaliação qualitativa e quantitativa dos defeitos foi realizada por meio de Image J. Os resultados do teste de concordância intra e inter-observadores tanto nas avaliações qualitativas e quantitativas foram predominantemente fracos. Os valores de Área Sob a Curva (ASC) variaram de 0.51 a 0.72 no i-CAT Gendex CB-500; e no ORTHOPANTOMOGRAPH OP300 variaram de 0.54 a 0.75, demonstrando desempenho diagnóstico ligeiramente superior. Nas imagens obtidas em aparelho com 120kVp (i-CAT Gendex CB-500) foram observados maior contraste em relação ao aparelho 90kVp (ORTHOPANTOMOGRAPH® OP300); em aparelho com o menor kVp (OP300) formaram mais artefatos e estes, degradaram a qualidade das imagens e influenciaram o desempenho diagnóstico das TCFCs na detecção e nas mensurações de perda óssea peri-implantar. Os protocolos de aquisições diferentes podem influenciar no aumento ou redução da formação dos artefatos.
Título en inglés
Comparison of accuracy and precision of linear measurements with different cone beam computed tomographic protocols
Palabras clave en inglés
Artifacts
Cone beam computed tomographic
Peri-implant bone defects
Resumen en inglés
One of the most important complications related to dental implant treatment is periimplantitis. Due to the structures overlapping inherited to periapical technique, in cases of buccal and lingual or palatal bone loss in peri-implantitis, the 3 dimensions observation exam like cone beam computed tomography(CBCT) is most indicated. The objective of this study was to evaluate the accuracy, specificity, sensitivity, interand intra-observer agreement and to determine the influence of the artifacts in the detection of the peri-implant bone defects simulated in human dry mandibles. The two CBCT devices with different acquisition protocols were used in this study: i-CAT Gendex CB-500 (120kVp, 5mA) and ORTHOPANTOMOGRAPH OP300 (90kVp, 6.3mA). Twenty-four cylindrical dental implants were placed and 16 defects were prepared only on buccal faces, the defect lengths ranged from 0.5mm to 15mm. For qualitative and quantitative assessment, only sagittal slices were evaluated by the observers, using Image J software. The results of intra and inter-observer agreement tests in both assessments were generally poor. The AUC values ranged from 0.51 to 0.72 on the i-CAT Gendex CB-500; and in the ORTHOPANTOMOGRAPH OP300 ranged from 0.54 to 0.75, showing slightly higher diagnostic performance. Higher contrast was observed in the 120 kVp device's images (i-CAT Gendex CB-500) when compared with the 90 kVp device's image (ORTHOPANTOMOGRAPH® OP300). The low kVp device (OP300), formed more artifacts which degraded the image quality and influenced the CBCT diagnostic performance in the detection and measurement of peri-implant bone loss. Different CBCT acquisition protocols may influence increasing or reducing artefact formation.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2018-11-13
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.