• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2010.tde-01042011-123435
Document
Author
Full name
Carlos Eduardo Pitta de Luca
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2010
Supervisor
Committee
Witzel, Andréa Lusvarghi (President)
Bolzan, Marcelo Costa
Silveira, Fernando Ricardo Xavier da
Title in Portuguese
Estudo do efeito da vibração no tratamento da disfunção temporomandibular através de um protótipo de placa vibratória oclusal
Keywords in Portuguese
A desordem temporomandibular
Biofeedback
Dor miofascial mastigatória
Estimulação vibratória
Placa oclusal
Abstract in Portuguese
Este estudo teve como objetivo estudar uma placa oclusalcom estimulação vibratória (POV) de base, para o tratamento da dor crônica miofascial. Foram selecionados 18 pacientes com mialgia crônica facial, de acordo com os Critérios para Diagnóstico em Pesquisa RDC . Os pacientes tinham entre 18 e 65 anos de idade, pertenciam ao sexo feminino e haviam usado placa estebilizadora acrílica por mais de 6 meses, e permaneciam com dor muscular. Foram excluídos pacientes com Disfunção Temporomandibular, que haviam feito uso de analgésicos ou de moduladores de sono, e pacientes desdentados parciais ou totais. A variável analisada foi a dor reportada pelos pacientes, usando a Escala Visual Analógica (EVA) de 100mm, medindo-se antes da instalação da POV, e um mes após o seu uso. Das 18 POV instaladas, 10 apresentaram falhas no mecanismo vibratório. As médias da EVA para os 8 pacientes que utilizaram a POV durante 1 mês foram de 56,62±22.82mm na aferição inicial e média de EVA final de 24,75±20,52mm, com p=0,011. Dos 8 pacientes apenas 4 concordaram com o uso da placa oclusal inativa (POI) por 30 dias, separadas por um período de wash-out de pelo menos 8 meses. Os níveis de dor da escala VAS foram a única variável analisada, e foram registrados antes e após o uso das placas. Foram utilizadas os testes t-teste pareado e ANOVA para medidas repetidas, para se obter os resultados estatísticos. No início do estudo, os níveis médios da VAS de dor antes de se utilizar a placa vibratória de maneira ativa e inativa foram 54,5±19,8 milímetros, e 44,0±13,6 milímetros, respectivamente. A comparação entre esses valores de referência não apresentaram diferença estatística (p> 0,05, teste t pareado). A variação média nos níveis de dor (VAS póspré) ao usar o mesmo tipo de placa, de maneira ativa e inativa foi de -42,0±-30,3 milímetros e 29,5±21,5 milímetros, e o t-teste revelou uma diferença significativa entre os dois grupos (p = 0,07). Foi feitauma nova análise, utilizando-se as mesmas medidas, através da Análise de Variância ANOVA, onde encontrou-se diferença estatisticamente significante (f(3,9)=7.543, p=0.008) antes do uso das placas ativas e das inativas. Entretanto, após o uso da correção com o teste de Bonferroni, foram encontrados resultados condizentes com aqueles obtidos na análise feita pelo programa do teste t. (p>0.05). Pode-se concluir que do uso da vibração como mecanismo de controle da DTM foi eficaz, mas a POV falhou na maioria dos casos devido a problemas mecânicos.
Title in English
Study of the effectiveness of vibratory plate in the treatment of dysfunction temporomandibular
Keywords in English
Biofeedback
Masticatory myofascial pain
Occlusal splint
Temporomandibular disorder
Vibratory stimulation
Abstract in English
This study aimed to study an occlusal splint with vibratory stimulation (VibsS) as standard, for the treatment of chronic myofascial pain. Were selected 18 patients with chronic facial myalgia, according to the Research Diagnostic Criteria for Temporomandibular Disorders, RDC-TMD.The patients were between 18 and 65years old, female, using stabilization splints for more than six months, and that remained with muscle pain. Were excluded patients with Temporomandibular Disorders, which had made use of analgesics or sleeps modulators and those who were partially or totally edentulous. The analyzed variable was pain reported by patients using visual analog scale (VAS) of 100mm, measuring before the installation of VibsS, and one month after its use. Were installed 18 VibsS; 10 failures in the vibrating mechanism.The mean VAS for the 8 patients who used the VibsS for 1 month were 56.62 ± 22.82mm to measure initial and final mean VAS of 24.75 ± 20.52 mm, p = 0.011. From these 8 patients, only four agreed to the use of an occlusal splints inactive for 30 days, separated by a wash-out period of at least 8 months. The levels of pain-VAS score was the only variable analyzed, and were recorded before and after use of the splints. Were used paired t-tests and ANOVA for repeated measures to obtain the statistics. At baseline, mean levels of VAS pain before using the vibrating splint active and inactive were 54.5±19.8 mm, and 44.0±13.6 mm, respectively. The comparison of these reference values showed no statistical difference (p> 0.05, paired t-test). The average change in pain levels (VAS post-pre) when using the same type of analysis, with active and inactive splints was -42.0±- 30.3 and 29.5 mm±21.5 mm, and the t-test showed a significant difference between the two groups (p = 0.07). After that, was made, a new analysis, using the same measures through the analysis of variance ANOVA, where were found a statistically significant difference (f (3,9) = 7543, p = 0.008) before the use of active boards and inactive. However, after using the correction with the Bonferroni test, we found results consistent with those obtained in the analysis performed by the test program t. (p>0.05). Conclusion: This study showed that is an effective use of vibration as a control mechanism of TMD, but this VibsS failed in most cases due to mechanical problems.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2011-04-08
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.