Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2005.tde-14102005-121119
Document
Author
Full name
Roberto Adrian Markarian
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2005
Supervisor
Committee
Sendyk, Claudio Luiz (President)
Henriques, Guilherme Elias Pessanha
Mori, Matsuyoshi
Title in Portuguese
"Biomecânica da transmissão de cargas a implantes unitários em função dos materiais protéticos: análise fotoelástica e dinâmica"
Keywords in Portuguese
Análise dinâmica
biomecânica
Fotoelasticidade
Implantes osseointegrados
materiais oclusais
prótese
Prótese dentária
Abstract in Portuguese
Em próteses sobre implantes, o recobrimento oclusal com materiais pouco rígidos como os acrílicos, é por vezes utilizado por supostamente reduzir a carga transmitida ao osso, entretanto não existe um consenso na literatura sobre a sua efetividade. O objetivo deste trabalho foi comparar, por análise fotoelástica e dinâmica, a transmissão de forças após a ação de cargas sobre próteses unitárias sobre implantes em função dos materiais protéticos. Confeccionou-se um modelo em resina fotoelástica com anatomia semelhante à região de pré-molares inferiores, contendo um implante de hexágono interno de 3,75 x 11,5 mm. Foram elaboradas três tipos de próteses em materiais com rigidez decrescente: 1- Metálica (alta rigidez); 2- Resina composta (rigidez moderada), 3- Com um disco de EVA interposto com h=2,5 mm (baixa rigidez). Por meio de um polariscópio circular, observou-se qualitativamente a tensão gerada no modelo durante a aplicação de forças axiais de 100 N, em regime compressivo, sobre cada tipo de prótese. Para a análise dinâmica, realizou-se um modelamento físico de cada um dos três sistemas implante-prótese com modelos de Voigt. A partir daí, uma representação matemática dos sistemas foi deduzida e resolvida, levando em consideração as propriedades mecânicas dos diferentes materiais testados, como o módulo de elasticidade (E), o coeficiente elástico (k) e a constante de amortecimento (c). Para representar uma carga mastigatória fisiológica, foi aplicado um pulso de força senoidal com duração de 0,25 s e intensidade máxima de 100 N, segundo a expressão ()) 8 cos( . 50 50 t t f π −=. Observou-se na análise fotoelástica que após a aplicação de 100N, surgiram tensões na região apical e na cervical dos implantes, com intensidade e localização similares entre os três tipos de prótese. A análise dinâmica mostrou que a força de 100N aplicada na prótese é totalmente transmitida ao implante instantaneamente. Os resultados das análises concordam entre si e mostram que não é possível amortecer as forças mastigatórias por meio dos materiais oclusais.
Title in English
Biomechanics load transmission single implants according to prosthetic materials photoelastic and dinamic analysis
Keywords in English
photoelasticity
biomechanics
Dental Phrostesis
dynamic anaylsis
occlusal materials
Osseointegrated implants
prosthesis
Abstract in English
Less rigid oclusal materials such as acrylic resins are often used in prosthesis over implants because they are supposed to diminish the loads transferred to the bone; however there is no scientific evidence to support this theory. The objective of this work was to compare by photoelastic and dynamic analysis the load transfer after oclusal loads over single prosthesis over implants, varying the oclusal materials. A photoelastic model was created, with an anatomy similar to an inferior premolar region. An internal hexagon implant (3,75 x 11,5 mm) was put in this model. Three different types of prosthesis were constructed with decrescent stiffness: 1- Metallic (higher stiffness); 2- Composite resin (moderate stiffness); 3- With an EVA disc interposed (fewer stiffness). By means of a circular polariscope, the stress generated in the model with a compressive axial load of 100 N, was observed for each prosthesis. For the dynamic analysis, a physical modeling of each implant-prosthesis was carried out with Voigt models. After that, a mathematical representation of the systems was deduced and solved, taking into account the mechanic properties of the different materials, like the elastic modulus (E), the elastic coefficient (k) and the damping constant (c). To represent a physiologic masticatory load, a senoidal force was applied, during 0,25 s and maximum load of 100 N, by the expression ()) 8 cos( . 50 50 t t f π −=. With the photoelastic analysis, it was observed that stresses were generated at the apical and cervical regions of implants, with similar intensity and patterns between the three types of prosthesis. The dynamic analysis, showed that the loads applied over the prosthesis are transferred to the implant instantaneously. The results of both anaylis are in agreement that it is not possible to damp masticatory loads by means of occlusal materials.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
TeseROBERTOMARKARIAN.pdf (684.26 Kbytes)
Publishing Date
2005-10-27
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.