Full name
Fernando Takashi Sima
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2007
Supervisor
Committee
Gil, Carlos (President)
Galvan, Ricardo
Navarro, Hamilton
Oliveira, Maria Angela Prestes
Sesma, Newton
Title in Portuguese
Estudo da validação e confiabilidade de um novo algômetro digital de pressão extra e intra-oral para detecção de sensibilidade dolorosa miofascial e da ATM
Keywords in Portuguese
Algômetro
Desordem craniomandibular
Sensibilidade dolorosa à pressão
Abstract in Portuguese
A proposta deste estudo foi desenvolver ferramentas que permitam um exame de palpação completo utilizando o algômetro e verificar a validade e confiabilidade intra e interexaminadores. Neste estudo foram examinados 80 indivíduos, sendo 40 pacientes sintomáticos que freqüentavam a clínica de prótese da Faculdade de Odontologia da Universidade de São Paulo, divididos em 20 mulheres e 20 homens com idade média de 43 anos e 40 voluntários assintomáticos divididos em 20 mulheres e 20 homens com idade média de 40 anos. Os pacientes foram examinados com um algômetro digital, ferramenta de palpação intra-oral e em forma de pinçamento em três sessões diferentes de exames com intervalo de uma semana entre si. Na primeira sessão os pacientes sintomáticos foram avaliados por um examinador, e este grupo foi denominado F1. Após uma semana, na segunda sessão, os mesmos pacientes foram reavaliados pelo mesmo examinador, e foram denominados grupoF2, após 30 minutos um segundo examinador avaliou os mesmos pacientes, com os resultados formou-se o grupoJ. Após uma semana, na terceira sessão, os 40 voluntários assintomáticos (controle) foram avaliados pelo examinador F, grupo denominado C. A validade do algômetro foi avaliada comparando-se grupoF2 x grupoC (sintomáticos x assintomáticos). A confiabilidade intra-examinador foi avaliada comparando-se grupoF1 x grupoF2 e a confiabilidade interexaminadores comparando-se grupoF2xgrupoJ. Após a aplicação de testes estatísticos a validade do algômetro foi comprovada, a confiabilidade intraexaminador foi considerada boa, porém a confiabilidade interexaminadores foi de aproximadamente 50%, mostrando que para se atingir altos níveis de confiabilidade é necessário um programa de calibragem e uma padronização da taxa de aplicação da força.
Title in English
Validity and reliability of a new digital algometer to detect extra and intra oral pressure pain threshold in miofascial and TMJ pain
Keywords in English
Algometer
Craniomandibular disorder
Pressure pain threshold
Abstract in English
The purpose of this study was to develop tools that allow a complete palpation examination using an algometer to evaluate validity and reliability. This study examined 80 subjects, 40 symptomatics patients from the school of Dentistry, University of São Paulo, divided in 20 women and 20 men, mean age 40 years, were examined using an eletronic algometer, intra-oral tool and pincer ? type pressure tool. The symptomatics patients were examinated in tree different sessions with intervals of one week. In the first session, an examiner (F1 group) evaluated the simptomatics patients. After one week, in the second session, the same examiner (F2 group) evaluated the same patients, 30 minutes later a second examiner evaluated the same patients (J group). One week later, in the third session, the first examiner (C group) evaluated 40 healthy volunteers. The validity of pressure digital algometer was obtained comparing F2 group x C group. The reliability intra examiner was obtained comparing F1 group x F2 group and the reliability inter examiners comparing F1 group x J group. After a statistic study, validity of the pressure digital algometer was obteined, good intra-examiner reliability was found but low interexaminer reliability was found, sugesting that to achieve hight levels of reliability a calibrating program and a padronization of pressure rate is necessary.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2007-09-05
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.