• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.23.2005.tde-03032005-112135
Documento
Autor
Nombre completo
Marcelo Alexandre Calamita
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2004
Director
Tribunal
Yamada, Roberto Nobuaki (Presidente)
Ferraz, Paulo Sergio Pedrosa
Moura Filho, Gastão Soares de
Navarro, Hamilton
Pereira, Marlene Fenyo Soeiro de Matos
Título en portugués
"Avaliação dimensional da região palatina em modelos de revestimento, após duplicação dos modelos de gesso para a confecção da estrutura metálica da prótese parcial removível, em função dos materiais duplicadores, revestimentos e da profundidade da abóbada palatina"
Palabras clave en portugués
Distorção
Materiais duplicadores
Prótese parcial
Revestimentos
Resumen en portugués
O objetivo deste estudo foi avaliar a região palatina em modelos de revestimento, após duplicação do modelo de gesso para a confecção da estrutura metálica da prótese parcial removível, em função dos materiais duplicadores, revestimentos e da profundidade da abóbada palatina. Foram utilizados 12 modelos mestres de gesso com duas diferentes profundidades da abóbada palatina, sendo seis de palato raso e seis de palato profundo. Os métodos de uplicação utilizados foram: A) Hidrocolóide reversível com revestimento aglutinado por sílica (GEL_SIL); B) Hidrocolóide reversível com revestimento aglutinado por fosfato (GEL_FOS) e C) Silicone de adição com revestimento aglutinado por fosfato (ADI_FOS). Assim, a partir de cada modelo mestre foi obtido um modelo de revestimento para cada um dos métodos descritos acima, sendo os 48 modelos resultantes aferidos com o aparelho de medição tridimensional de coordenadas e os dados analisados estatisticamente pelo método split-plot. Avaliando-se os resultados obtidos concluiu-se que: 1) Todos os métodos de duplicação produziram algum grau de imprecisão nos locais avaliados; 2) O método GEL_FOS apresentou mínimas diferenças médias em relação ao modelo mestre; 3) O método GEL_SIL apresentou diferenças médias positivas em relação ao modelo mestre, não estatisticamente significativas em relação ao método GEL_FOS; 4) O método ADI_FOS apresentou diferenças médias negativas em relação ao modelo mestre, estatisticamente significativas em relação aos métodos GEL_FOS e GEL_SIL e 5) A profundidade da abóbada palatina não influenciou significativamente os resultados obtidos.
Título en inglés
Dimensional evaluation of the palatal area in investment casts after the duplication of stone casts for removable partial denture framework construction in relation to the duplicating materials, investments and depth of the palatal vault.
Palabras clave en inglés
Distortion
Duplication–Evaluation
Investment casts
Partial dentures
Resumen en inglés
The aim of this study was to evaluate the palatal area in investment casts after the duplication of stone casts in relation to the duplicating materials, investments and the depth of the palatal vault. Twelve master stone casts were used with two different palatal vault depths, six with a shallow palatal vault and six with a deep palatal vault. The duplicating methods used were: A) Reversible hydrocolloid with silica bonded investment (GEL_SIL); B) Reversible hydrocolloid with phosphate bonded investment (GEL_FOS), and C) Addition silicone with phosphate bonded investment (ADI_FOS). Thus, one investment cast was obtained from each master cast for each of the methods described above. The 48 resulting models were measured with a three-dimensional coordinate measurement machine, and the data were analyzed by the split-plot method. After evaluating the results we concluded that: 1) All investment casts showed some degree of distortion in the areas measured; 2) The GEL_FOS method showed the smallest average differences in relation to the master cast; 3)The GEL_SIL method showed positive, not statistically significant average differences in relation to the GEL_FOS method; 4) The ADI_FOS method showed negative, and statistically significant differences in relation to the GEL_FOS and GEL_SIL methods, and 5) The depth of the palatal vault did not influence the results significantly.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
TeseCompleta.pdf (832.14 Kbytes)
Fecha de Publicación
2005-03-14
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.