Thèse de Doctorat
DOI
https://doi.org/10.11606/T.23.2007.tde-03012008-104903
Document
Auteur
Nom complet
Paulo Mazini Neto
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Paulo, 2007
Directeur
Jury
Nakamae, Atlas Edson Moleros (Président)
Guarnieri, Tatiana de Carvalho
Homem, Maria da Graca Naclerio
Menezes, Joao Carlos Padilha de
Poletto, Luiz Thadeu de Abreu
Titre en portugais
Avaliação da área de contato dos dentes artificiais em função da forma oclusal e da forma das arcadas na posição de máxima intercuspidação e nos movimentos excursivos
Mots-clés en portugais
Area de contato
Dentes artificiais
Movimentos excursivos
Oclusão
Prótese total
Resumé en portugais
Nesta pesquisa, foi analisada a área dos contatos oclusais, em posição de máxima intercuspidação e nos movimentos excursivos de protrusão e lateralidades direita e esquerda. Para tanto, foram utilizados dentes artificiais anatômicos e funcionais, nacionais e importados, montados em arcadas de formas triangular, quadrada e oval. Após o devido ajuste oclusal e, a partir das imagens digitalizadas das próteses em cera, foi realizada a mensuração das áreas demarcadas pelo papel carbono, empregando-se o software Leica Qwin® 550. Os resultados, em milímetros quadrados, foram submetidos à análise estatística (ANOVA e Teste de Tukey). A partir das relações estabelecidas entre os fatores, pode-se concluir que, tanto para o modelo superior quanto para o modelo inferior, as áreas totais em MIC foram maiores que as áreas totais em protrusão. Ainda em protrusão, os segmentos posterior direito, anterior e posterior esquerdo apresentaram áreas iguais. Nos movimentos de lateralidade direita e esquerda, as áreas totais foram menores ou iguais às áreas totais obtidas em MIC. Nas lateralidades, as áreas no lado de trabalho foram maiores que as áreas no lado de balanceio. Na lateralidade direita, a área no lado de trabalho foi maior que a área direita do registro obtido em MIC. Na lateralidade esquerda, a área no lado de trabalho foi maior que a área do segmento esquerdo do registro em MIC. Na lateralidade direita, a área no lado de balanceio foi menor que a área do segmento esquerdo do registro em MIC. Na lateralidade esquerda, a área no lado de balanceio foi menor que a área do segmento direito do registro em MIC.
Titre en anglais
Measurement of occlusal area in prosthetic teeth according to tooth form, arch form and during maximum voluntary clenching and excursive movements
Mots-clés en anglais
Artificial tooth
Complete denture
Dental occlusion
Excursive movements
Resumé en anglais
This study regards the measurement of occlusal area of prosthetic arches, all assembled in triangular, squared and oval arch forms, with functional prosthetic teeth from different manufacturers; occlusal area was measured during maximum voluntary clenching (MVC), protrusive and laterotrusive (right and left) movements. Following arch assembly and occlusal adjustment, occlusal contacts for MVC and eccentric movement were marked by carbon paper, and occlusal areas were measured by means of analysis of standardized digital images and appropriate software (Leica Qwin® - 550). Occlusal areas were measured in square millimiters, and resulting values underwent statistical tests (ANOVA and Tukey). Statistical results showed that, for both upper and lower arches, occlusal areas during MVC were greater than during protrusion; also during protrusion, buccal tooth segments, both right and left, showed similar areas. During right and left laterotrusion, occlusal areas were smaller in comparison to MVC, and working sides presented larger areas than balancing sides. During laterotrusion to the right side, occlusal areas measured at the working side were larger than during MVC (right side), and same was observed for the left side during laterotrusion to the left. During laterotrusion to the right side, occlusal areas measured at the balancing side were smaller than during MVC (left side), and similar differences were observed during laterotrusion to the left side.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
PauloMazini.pdf (5.22 Mbytes)
Date de Publication
2008-04-01
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.