• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.23.2015.tde-15042015-120955
Documento
Autor
Nombre completo
Lívia Tosi Trevelin
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Paulo, 2015
Director
Tribunal
Matos, Adriana Bona (Presidente)
Chavez, Victor Elias Arana
Navarro, Ricardo Scarparo
Título en portugués
Análise morfológica da dentina irradiada pelo laser de Er:YAG (SSP) com diferentes larguras de pulso
Palabras clave en portugués
Dentina
Laser de Er:YAG
Microscopia Eletrônica de Varredura
Pré-tratamento dentinário
Preparo cavitário em dentina
Resumen en portugués
Este estudo se propôs a analisar as características morfológicas da dentina humana irradiada com laser de Er:YAG utilizando diferentes larguras temporal de pulso nos protocolos de preparo cavitário e pré-tratamento da dentina. Foram utilizados 18 molares humanos que foram seccionados no sentido mésio-distal e amelocementário obtendo-se um disco plano de dentina. Em seguida foram lixados com uma sequência decrescentes de lixas para padronizar os espécimes em 2mm de espessura. Os grupos experimentais foram compostos a partir de 2 fatores de variação: 1) indicação clínica - preparo cavitário (E=200mJ/20Hz), e pré-tratamento (E=80mJ/2Hz); e 2) largura temporal de pulso - 50, 300 e 600µs. Assim formaram-se 6 grupos experimentais com (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); G6(E=80mJ/2Hz/600µs). Os espécimes foram irradiados com o laser de Er:YAG com comprimento de onda de 2,94µm, de modo não contato, com um distância de 7mm do feixe de saída, sob irrigação de 60ml/min de água e 40ml/min de ar. Após a irradiação, os espécimes foram processados e destinados à avaliação descritiva das imagens obtidas em Microscopia Eletrônica de Varredura (MEV), nos diferentes grupos experimentais. A análise morfológica dos grupos irradiados revelou uma superfície irregular, ausência de smear layer que expõe a abertura dos túbulos dentinários, dentina peritubular evidente e, sem indícios de carbonização e derretimento para todos os protocolos utilizados. Os resultados deste estudo in vitro mostraram que a irradiação com o laser de Er:YAG promoveram um padrão morfológico microrretentivo característico de ablação para todos os grupos testados e os grupos G1 e G4, que utilizaram a menor largura temporal de pulso (50 ?s), apresentaram uma superfície mais rugosa quando comparados aos demais grupos. Por fim, podemos concluir que a largura temporal de pulso influência nas características morfológicas da dentina irradiada nas diferentes indicações clínicas testadas, preparo cavitário e pré-tratamento. A menor largura de pulso (50 µs) produz uma morfologia mais irregular quando comparada as maiores larguras de pulsos (300 e 600 µs).
Título en inglés
Effect of Er:YAG (SSP) laser pulse widths on dentin - morphological analysis
Palabras clave en inglés
Cavity preparation
Dentin
Laser of Er:YAG
Pretreatment on dentin
Scanning Electron Microscopy
Resumen en inglés
This study evaluated the morphological characteristics of Er:YAG laser irradiated dentin using different temporal pulses width on the protocols of cavity preparation and dentin pretreatment. Eighteen human molars were cut longitudinally in a mesiodistal direction and amelocemental junction providing dentin disks. Samples were polished in a decreasing silicon carbide paper to obtain standard 2mm thick disks. The experimental groups were divided by two variables: 1) clinical protocol - cavity preparation (E=200mJ/20Hz) and pretreatment (E=80mJ/2Hz); and 2) temporal pulse width - 50, 300 and 600µs. Therefore, six experimental groups were (n=3): G1(E=200mJ/20Hz/50µs); G2(E=200mJ/20Hz/300µs); G3(E=200mJ/20Hz/600µs); G4(E=80mJ/2Hz/50µs); G5(E=80mJ/2Hz/300µs); and G6(E=80mJ/2Hz/600µs). The samples were irradiated with the Er.YAG laser using wave-length of 2.94µm, in a non contact mode at a focal distance of 7mm from the target point under continuous water spray of 60-40ml/min. After the irradiation, the samples were processed and evaluated by scanning electron microscopic evaluation (SEM). The morphological analysis on the irradiated groups showed an irregular dentin surface, without smear layer, exposed dentinal tubules apertures, evidenced peritubular dentin, without carbonization and melting signs for all groups. A microretentive morphological pattern, characteristic of the ablation process could be observed in all groups. However, groups G1 and G4, that used 50?s of temporal pulse width, presented a greater irregularity when compared to other groups. In conclusion, the temporal pulse width interfere on the morphological characteristic of the irradiated dentin, regardless of clinical protocol, cavity preparation and pretreatment. The shorter the pulse width (50µs), the greater the surface irregularity.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2015-05-06
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.