• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.23.2017.tde-06032017-101941
Document
Author
Full name
Eric Mayer dos Santos
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Paulo, 2016
Supervisor
Committee
Vieira, Glauco Fioranelli (President)
Agra, Carlos Martins
Noritomi, Pedro Yoshito
Silva, Patricia Moreira de Freitas Costa e
Title in Portuguese
Comparação da eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares: uma análise de elementos finitos tridimensional
Keywords in Portuguese
Análise de Elementos Finitos
Análise do Estresse Dentário
Técnica para Retentor Intrarradicular
Abstract in Portuguese
Elementos dentais endodonticamente tratados geralmente necessitam de retentores intrarradiculares para prover retenção e suporte ao processo restaurador. O objetivo deste estudo foi comparar a eficiência na distribuição de tensões de diferentes modelos de retentores intrarradiculares, através do método dos elementos finitos. Um modelo tridimensional de elementos finitos foi desenvolvido para representar um incisivo central superior endodonticamente tratado e restaurado com uma coroa total cerâmica, e quatro tipos diferentes de pinos pré-fabricados (dois convencionais, e dois modelos customizados) foram inseridos sob esse modelo e comparados quanto à distribuição das tensões às quais foram submetidos. Os quatro pinos diferem em formato e material de composição. O primeiro é um pino pré-fabricado metálico customizado referente à uma patente, com porção coronária anatômica (com curvaturas e formatos semelhantes à coroa anatômica) e flange rosqueável. O segundo pino pré-fabricado é semelhante em formato ao primeiro pino, mas será composto por fibra de vidro. O terceiro é um pino metálico pré-fabricado convencional, sem presença de flange. O quarto pino é semelhante ao terceiro pino em formato, mas será composto por fibra de vidro. Foi aplicada sobre os modelos uma mesma força estática média de 100 N com uma angulação de 135 graus ao longo eixo do dente no centro da face palatina do modelo, com o objetivo de simular a carga mastigatória e obter a distribuição das tensões. A avaliação apresentou os resultados considerando os critérios de Von Mises e tensões máximas principais. Os resultados mostraram que os pinos metálicos customizados resultaram em menores tensões à dentina e à estrutura coronária quando comparados aos pinos convencionais, e que ambos os pinos metálicos apresentaram menores tensões à estrutura coronária se comparados aos pinos em fibra de vidro. Em relação à estrutura dentinária, os pinos metálicos e os pinos em fibra de vidro apresentaram resultados semelhantes quanto à distribuição de tensões. Os modelos em fibra de vidro apresentaram resultados semelhantes em ambas as avaliações. Conclui-se que os modelos customizados foram superiores aos convencionais quando compostos pela liga metálica, mas semelhantes quando compostos por fibra de vidro.
Title in English
Efficiency comparison in stress distribution of different post types: a 3D finite element analysis
Keywords in English
Dental Stress Analysis
Finite Element Analysis
Post and core technique
Abstract in English
Endodontically treated teeth commonly require a post to provide retention and support to the restorative process. The aim of this study was to compare the efficiency of the distribution stresses of different models of posts through the finite element method. A three-dimensional finite element model was developed to represent an endodontically treated maxillary central incisor restored with a ceramic crown, and four different types of prefabricated posts (two conventional and two customized models) have been inserted in that model and compared regarding the distribution of the stresses to which they were subjected. The four posts differ in size and material composition. The first is a custom metal prefabricated post relating to a patent, with anatomical coronal portion (with curvatures and format similar to the anatomical crown) and threaded flange. The second prefabricated post is similar in format to the first post, but is composed of fiberglass. The third is a conventional prefabricated metal post without the flange. The fourth post is similar to the third in format, but is composed of fiberglass. It was applied on the models the same average static occlusal force of 100N with an angle of 135 degrees to the tooth long axis in the palatal surface of the crown, with an objective of simulate the masticatory load and obtain the stress distribution. The evaluation presented the results considering the Von Mises and Maximum principal stress criteria. The results showed that the customized metal posts resulted in lower stresses to dentin and coronal tooth structure when compared to conventional posts, and both metallic posts had lower stresses in the coronal portion structure compared to glass fiber posts. Regarding the dentinal structure, metal posts and fiberglass posts showed similar results of stresses. The fiberglass models showed similar results in both evaluations. We conclude that the custom models were superior to conventional posts when composed by metal, but similar when composed of fiberglass.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2017-03-22
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.