Author
Full name
Rosicler Xelegati de Padua
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2016
Supervisor
Committee
Évora, Yolanda Dora Martinez (President)
Gabriel, Carmen Silvia
Matsuda, Laura Misue
Vituri, Dagmar Willamowius
Title in Portuguese
Eventos adversos relacionados ao uso de equipamentos e materiais na assistência de enfermagem a pacientes hospitalizados
Keywords in Portuguese
Assistência de enfermagem
Equipamentos e provisões hospitalares
Eventos adversos
Abstract in Portuguese
O uso de equipamentos e materiais na assistência à saúde contribui para a segurança do paciente e para o bom desempenho dos profissionais, porém não se pode desconsiderar o potencial de riscos trazido pela utilização destes e a possibilidade de ocorrências de eventos adversos (EA). O objetivo geral dessa investigação foi analisar o uso de equipamentos e materiais na assistência de enfermagem e sua relação com a ocorrência de EA. Trata-se de um estudo quantitativo, descritivo, com delineamento de pesquisa não-experimental, dividido em três etapas: 1ª) Revisão integrativa da literatura com busca nas bases de dados PubMed, CINAHL e LILACS; 2ª) Consulta às fichas informatizadas de notificação de EA de um hospital privado acreditado, registradas no período de 01/01/2011 a 30/06/2015, com vistas à seleção e análise dos eventos ocasionados pelo uso de equipamentos e materiais; 3ª) Elaboração, validação e aplicação de um instrumento de coleta para investigar os EA relacionados aos equipamentos e materiais e as estratégias utilizadas para propiciar o uso seguro desses dispositivos. Os principais resultados encontrados foram: 1ª) Seleção e análise de sete artigos, agrupados nas categorias: "Métodos de registro, taxas de ocorrência e tipos de EA" e "EA ocorridos no transporte de pacientes críticos" (ambos relacionados a equipamentos e materiais); 2ª) Constatado a notificação de 1.065 EA, sendo 180 (16,9% do total) relacionados ao uso de equipamentos e materiais na assistência de enfermagem: perda de sonda de alimentação (SNE, SNG, SOG e gastrostomia) (45,0%), perda de cateter venoso central (15,5%), lesão de pele (10,5%), extubação acidental (10,0%), perda de sonda vesical de demora (4,4%), erros de administração de medicamentos (bomba de infusão) (3,9%), perda de dreno (2,8%), tecnovigilância (2,8%), obstrução de cânula de traqueostomia (1,7%), perda de cateter de pressão arterial invasiva (1,7%), quedas (1,1%) e perda de cateter de analgesia (0,5%); 3ª) O instrumento foi elaborado, validado por cinco juízes e aplicado a 22 enfermeiros, apresentando as seguintes respostas: a) sobre o funcionamento inadequado ou o não funcionamento dos equipamentos, os mais citados foram bomba de infusão, cama elétrica, esfigmomanômetro, monitor multiparamêtrico, oxímetro de pulso e ventilador pulmonar mecânico; b) os EA provocados pela utilização inadequada ou incorreta de materiais foram lesão de pele, perda de sonda de alimentação, perda de cateter venoso central, perda de drenos, extubação acidental, perda de cateter de pressão arterial invasiva e perda de cateter de pressão intra-craniana; c) os EA ocorreram durante mudança de decúbito, administração de medicamentos, higiene corporal, transporte intra-hospitalar, atendimento de Urgências/Emergências e troca da fixação de cateteres e sondas; d) as estratégias preventivas prioritárias foram capacitação dos profissionais de enfermagem (na admissão e na aquisição de um novo equipamento ou material), utilização de protocolos assistenciais de enfermagem e manutenção preventiva / teste de qualidade prévio dos dispositivos. A aquisição de aparatos tecnológicos modernos se torna nula se não for acompanhada do investimento em capacitação dos profissionais de enfermagem das instituições de saúde e da preocupação em prevenir e minimizar a ocorrência de EA relacionados ao uso de equipamentos e materiais na assistência ao paciente
Title in English
Adverse events related to the use of equipment and materials in nursing care to hospitalized patients
Keywords in English
Adverse events
Equipment and hospital supplies
Nursing care
Abstract in English
The use of equipment and materials in health care contributes to patient safety and to the good performance of professionals, but the potential for risks brought by the use of them and the possibility of adverse event (AE) occurrences cannot be ignored. This study aimed to analyze the use of equipment and materials in nursing care and its relationship to the AE occurrence. This is a quantitative, descriptive, non-experimental research design study, divided into three stages: 1) Integrative review with search in the databases PubMed, CINAHL and LILACS; 2) Consultation in computerized records of AE notification in an accredited private hospital, which were registered from January 1, 2011 to June 30, 2015, in order to select and to analyze events caused by the use of equipment and materials; 3) Development, validation and application of a data collection tool to investigate the AE related to equipment and materials and the strategies used to promote the safe use of these devices. The main results were: 1) Selection and analysis of seven articles, grouped into the following categories: "Registration methods, occurrence rates and types of AE" and "AE occurred in the transport of critically ill patients" (both related to equipment and materials); 2) After verifying the notification of 1,065 AE, and 180 (16.9% of the total) related to the use of equipment and materials in nursing care: feeding tube loss (SNE, SNG, SOG and gastrostomy) (45,0%), central venous catheter loss (15.5%), skin lesions (10.5%), accidental extubation (10.0%), bladder catheter loss (4.4%), medication administration errors (infusion pump) (3.9%), surgical drain loss (2.8%), technical surveillance (2.8%), tracheostomy tube obstruction (1.7%), invasive arterial pressure catheter loss (1,7%), falls (1.1%) and analgesia catheter loss (0.5%); 3) The instrument was developed, validated by five judges and applied to 22 nurses, with the following answers: a) about the improper functioning or non-functioning of equipment, the most common were infusion pump, electric bed, sphygmomanometer, multiparameter monitor , pulse oximeter and mechanical pulmonary ventilator; b) the AE caused by improper or incorrect use of materials were skin lesions, feeding tube loss, central venous catheters loss, surgical drain loss, accidental extubation, invasive arterial pressure catheter loss and intracranial pressure catheter loss; c) the EA occurred during change of decubitus, medication administration, personal hygiene, intra-hospital transport, Urgency/Emergency care and exchange of fixation of catheters and probes; d) priority preventive strategies were training of nursing professionals (on admission and in the purchase of new equipment or materials), use of nursing care protocols and preventive maintenance/quality prior testing of the devices. The acquisition of modern technological devices becomes invalid if it is not accompanied by investment in training of nursing professionals in health institutions and concerned to prevent and minimize the occurrence of adverse events related to the use of equipment and materials in patient care
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-10-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.