• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.22.2019.tde-05122018-204232
Document
Author
Full name
Daniel Martinez Lana
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
Ribeirão Preto, 2018
Supervisor
Committee
Ancheschi, Leila Maria Marchi Alves (President)
Carnio, Evelin Capellari
Magnabosco, Patricia
Papoti, Marcelo
Title in Portuguese
Confiabilidade de um circuito multimodal incremental na determinação do limiar anaeróbio de idosos por meio da dosagem do lactato sanguíneo
Keywords in Portuguese
Exercício em circuitos ; Hipotensão pós-exercício ; Idoso ; Limiar anaeróbio
Abstract in Portuguese
A prática regular de exercício físico traz inúmeros benefícios para os idosos, mas é necessário identificar uma prescrição de treinamento que possa ser realizada de maneira segura e eficaz por esta população. O Treinamento Multimodal é uma alternativa para estimular as capacidades e habilidades físicas importantes para a manutenção da saúde e autonomia no envelhecimento. O objetivo deste estudo, de abordagem quantitativa e delineamento quase-experimental, foi medir a confiabilidade de um circuito multimodal incremental na determinação do limiar anaeróbio (LAN) de idosos por meio da dosagem do lactato sanguíneo. O estudo foi aprovado por Comitê de Ética em Pesquisa. Foram identificadas variáveis sociodemográficas e clínicas. As variáveis clínicas foram medidas antes, durante e após sessões de treinamento em um circuito multimodal. Para as análises descritivas, foram calculadas as frequências absolutas, porcentagens, medianas, médias e desvio padrão. Para a análise de confiabilidade intraobservador e de concordância, foram utilizados o Coeficiente de Correlação Intraclasse (CCI) e o teste de concordância Bland-Altman, usando o pacote estatístico SPSS® V24. Para a identificação da igualdade de médias no teste e no reteste foram utilizados os testes paramétricos t-pareado e One-way ANOVA medidas repetidas, para variáveis contínuas e com distribuição normal, tomadas nos momentos antes e depois. Para os casos onde as suposições de normalidade e/ou esfericidade não foram atendidas, foram utilizados os testes não paramétricos de Wilcoxon ou Friedman. A intensidade do limiar anaeróbio (ILAN) e a Frequência Cardíaca na Intensidade do Limiar Anaeróbio (FCILAN) foram identificadas a partir de três critérios. Participaram do estudo 20 idosos, na maioria mulheres, com idade entre 60 e 65 anos, de cor branca, convivendo com companheiro, com mais de 12 anos de escolaridade, aposentados. Ao testar a reprodutibilidade da ILAN em dois momentos distintos com o mesmo avaliador, observamos que a média dos escores obtidos no teste e reteste foi semelhante (>,05) indicando boa correlação entre os pares analisados (r = ,77 a ,91). Nossos resultados também mostraram alta confiabilidade em todos os critérios adotados para determinação do LAN (CCI=,86 a ,95), além de boa concordância das medidas teste e reteste para o LAN2 do 1° e 3° critérios por meio do método de análise Bland-Altman. Identificamos redução da pressão arterial na primeira hora após o treinamento em circuito, em comparação com os valores pré-intervenção, nos momentos teste e reteste. O principal achado de nosso estudo se deu pela confiabilidade e concordância entre as medidas teste-reteste para as variáveis estudadas, sugerindo adequação do circuito multimodal incremental na determinação do LA de idosos por meio da dosagem do Lactato Sanguíneo
Title in English
Reliability of an incremental multi-modal circuit in the determination of the anaerobic threshold of elderly people through the dosage of the blood lactate
Keywords in English
Aged ; Anaerobic threshold ; Circuit-based exercise ; Post-exercise hypotension
Abstract in English
Regular physical activity brings several benefits to elderly people, but it's necessary to identify a training prescription that can be performed in a safe and effective manner for this population. The Multimodal Training is an alternative to stimulate physical skills and abilities important to maintaining health and autonomy in aging. The purpose of this study, with quantitative approach and quasi-experimental delineation, was to measure the reliability of an incremental multimodal circuit in the determination of the anaerobic threshold (ANT) of elderly people through blood lactate dosage. The study was approved by the Ethics in Research Committee. Social demographic clinical variables were found. Clinical variables were measured before, during and after the training sessions in a multi-modal circuit. For descriptive analysis, absolute frequencies, percentages, medians, averages and standard deviation were calculated. For intra-observer reliability and agreement analysis, we used the Interclass Correlation Coefficient (ICC) and Bland-Altman agreement test, using statistical package, SPSS® V24. To the measures equality identification in the test and retest were used the t-paired parametrics and One-way ANOVA repeated measures, to continuous variables and with normal distribution, taken moments before and after. To the cases where normality and/or spherecity were not satisfied, we used Wilcoxon or Friedman non-parametric tests. The anaerobic threshold intensity (ATI) and the heart rate in the anaerobic threshold intensity (HRATI) were identified according to three criteria. Participated in the study 20 elderly people, mostly women, between the ages of 60 and 65 years old, white colored, living with a partner, with more than 12 years of schooling, retired. When testing the reproducibility of ATI in two different times with the same evaluator, we observed the measure of the obtained scores in the test and retest was similar to (>,05), indicating a good correlation between the analyzed pairs (r = ,77 a ,91). Our results also showed high reliability in all adopted criteria to determine ATI (CCI=,86 a ,95), in addition to the good agreement of the test and retest measures to the ATI2 of the first and third criteria through Bland-Altman analysis method. Was identified arterial pressure reduction in the first hour after the circuit training, compared with preintervention values, in the test and retest moments. The main discovery was given through reliability and agreement between measures test-retest to the studied variables, suggesting adjustment of the incremental multimodal circuit in the determination of the elderly people ATI through blood lactate dosage
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2019-01-17
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.