• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2013.tde-11092013-160301
Document
Auteur
Nom complet
Livia Maria de Castro Sousa
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2013
Directeur
Jury
Gonçalves, Débora (Président)
Carvalho, Antonio José Felix de
Moraes, Marli Leite de
Titre en portugais
Estudos sobre a imobilização da polifenoloxidase em filmes de polipirrol/poli-3-metiltiofeno e uso destes filmes em biossensores amperométricos
Mots-clés en portugais
Biossensores
Catecol
Polimetiltiofeno (PMET)
Polipirrol (PPI)
Superoxidação
Tirosinase
Resumé en portugais
Nesta dissertação, foram estudados os métodos de síntese de filmes poliméricos como matrizes hospedeiras da enzima tirosinase vislumbrando o desenvolvimento de biossensores mais seletivos e duradouros na detecção de compostos fenólicos. Os polímeros utilizados e preparados por cronoamperometria em acetonitrila foram: polipirrol (PPI), polimetiltiofeno (PMET) e copolímero PPI-PMET. Os filmes PPI-PMET apresentaram características intermediárias às dos filmes PPI e PMET, conforme se verificaram em espectros na região do infravermelho (FTIR), voltametria cíclica e microscopia de força atômica (AFM), evidenciando, assim, a formação de uma nova matriz polimérica. O processo de superoxidação do filme PPI-PMET foi estudado visando a uma imobilização mais eficiente da enzima, quando se obteve uma condição na qual a superoxidação ocorre somente nas cadeias de PPI. Biossensores amperométricos foram preparados a partir do uso da tirosinase extraída do abacate como fonte enzimática por imobilização física e realizada de maneiras diferentes em filmes não superoxidados e superoxidados. Foi feita a otimização das respostas dos filmes variando-se o pH, potencial de trabalho, concentração da enzima e tempo de imobilização da enzima para a detecção de catecol. Os resultados indicaram que a superoxidação do PPI nos filmes PPI-PMET favoreceu a imobilização da enzima, embora não fosse tão eficiente quando se comparou aos filmes com o PPI não superoxidado. Contudo, os biossensores, em geral, apresentaram grande sensibilidade ao catecol, com um limite de detecção baixo, da ordem de 0,12 µmol/L.
Titre en anglais
Studies on the immobilization of polyphenoloxidase polypyrrole/poly-3-methylthiophene films and their use in amperometric biosensors
Mots-clés en anglais
Biosensors
Catechol
Overoxidized
Polymethylthiophene (PMET)
Polypyrrole (PPY)
Tyrosinase
Resumé en anglais
The synthesis methods of polymer films as host matrices of the enzyme tyrosinase were studied in this dissertation. It was expected the development of selective and everlasting biosensors for the detection of phenolic compounds. The used polymers were prepared by chronoamperometry in acetonitrile as followed: polypyrrole (PPI), polymethylthiophene (PMET) and copolymer PPI-PMET. The PPI-PMET films showed intermediate characteristics as the PPI and PMET films, as observed in the infrared spectra (FTIR), cyclic voltammetry and atomic force microscopy (AFM), thus indicating the formation of a new polymeric matrix . The process of overoxidized of PPI-PMET film was studied in order to achieve a more efficient immobilization of the enzyme, whilst it was achieved a condition in which overoxidized occurs only in the PPI chain. Amperometric biosensors were prepared from the use of tyrosinase extracted from avocado as an enzyme source by physical immobilization and performed in different ways in both overoxidized and non-overoxidized films. It was performed the optimization of the responses of the films by varying pH, operacuonial potential, enzyme concentration and time in the enzyme immobilization for the detection of catechol. The results showed that the overoxidized PPI in the films PPI-PMET favored the immobilization of the enzyme, although not as efficient when compared to the films with nom overoxidized PPI. Neverthless, the catechol biosensors showed a high sensitivity with a low detection limit in the order of 0.12 µmol/L.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
DFL.pdf (3.44 Mbytes)
Date de Publication
2013-09-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.