Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2016.tde-06052016-084651
Document
Author
Full name
João Paulo Sachetto
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2016
Supervisor
Committee
Cavalheiro, Carla Cristina Schmitt (President)
Bosquetti, Péricles
Sentanin, Franciani Cassia
Title in Portuguese
Efeito do tratamento térmico de STx-1b-Li+ na condutividade de filmes de STx-1b-Li+ /Alginato de sódio
Keywords in Portuguese
Alginato de sódio
Argila
Tratamento térmico
Abstract in Portuguese
Neste trabalho foram estudados os efeitos causados pelo tratamento térmico na argila STx-1b-Li+ na condutividade de filmes argila/alginato de sódio. O argilomineral STx-1b foi submetido à substituição isomórfica do cátion Na+ por Li+ e posteriormente ao tratamento térmico em diferentes temperaturas. As argilas STx-1b-Li+ não tratada e tratada termicamente foram caracterizada por difração de raios-X (DRX) e termogravimetria (TG). As curvas TG mostraram que o argilomineral STx-1b-Li+ apresentou três perdas de massa que podem ser atribuídas à água adsorvida na argila, a água de hidratação dos íons Li+ e a água estrutural da argila. Para as argilas STx-1b-Li+ tratadas termicamente não foi observado a perda de massa associada à água quimicamente ligada aos contra-íons Li+. Estes resultados estão em concordância com os obtidos por DRX, onde observou-se uma diminuição no espaçamento interlamelar nas argilas tratadas termicamente. Em adição, foram preparados filmes de alginato de sódio com as argilas STx-1b-Li+ não tratada e tratada termicamente e estes foram caracterizados por calorimetria exploratória diferencia (DSC) e espectroscopia de impedância eletroquímica (EIE). As curvas DSC mostraram um aumento na temperatura de transição vítrea (Tg) dos filmes com o aumento da temperatura utilizada no tratamento das argilas. Este aumento nos valores de Tg é um indicativo que a mobilidade das cadeias diminuiu nos filmes polímero/argila que contém argilas tratadas em temperaturas mais elevadas. A espectroscopia de impedância eletroquímica (EIE) foi usada para avaliar-se a condutividade iônica dos filmes. Os resultados indicaram que os filmes contendo argilas que foram tratadas com temperaturas mais altas apresentaram menor condutividade.
Title in English
Effect of heat treatment of STx-1b-Li+ on the conductivity of STx-1b-Li+ /Sodium alginate films
Keywords in English
Clay
Heat treatment
Sodium alginate
Abstract in English
In this work the effects caused by the heat treatment in STx-1b-Li+ clay on the conductivity of sodium alginate/clay were studied. The clay mineral STx-1b was submitted to isomorphous substitution of the Na+ for Li+ cation and subsequently to heat treatment at different temperatures. The STx-1b-Li+ clays untreated and heats treated were characterized by X-ray diffraction (XRD) and Thermogravimetric Analysis (TG). The TG curve showed that the clay mineral STL-1b-Li+ had three mass losses which can be attributed to adsorbed water in the clay, the water of hydration of the Li+ ions and structural clay water. To STx-1b-Li+ clays heat treated there were no mass loss associated to the water chemically bound to Li+ counter ions. These results are in agreement with those obtained by XRD, which it was observed a decrease in interlayer spacing in the heat treated clay. In addition, they were prepared sodium alginate films with STx-1b-Li+ clays untreated and heat treated and these films were characterized by Differential Scanning Calorimetry (DSC) and Electrochemical Impedance Spectroscopy (EIS). DSC curves showed an increase in glass transition temperature (Tg) of the films with temperature increasing used in the treatment of clays. This increase in Tg value is an indicative that the mobility of the chains had decrease in the polymer/clay films which contains heat treated clays at higher temperatures. The electrochemical impedance spectroscopy (EIS) was used to evaluate the ionic conductivity of the films. The results indicate that films containing clays which have been treated at higher temperatures had lower conductivity.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2016-05-11
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI