• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Dissertação de Mestrado
DOI
https://doi.org/10.11606/D.18.2015.tde-01042015-202704
Documento
Autor
Nome completo
Pablo Felipe Marins Finotti
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2015
Orientador
Banca examinadora
Chinelatto, Marcelo Aparecido (Presidente)
Carvalho, Antonio José Felix de
Costa, Lidiane Cristina
Título em português
Estudo do comportamento mecânico e biocompatibilidade de blendas PLA/PCL compatibilizadas e não-compatibilizadas
Palavras-chave em português
Bioimplantes
Bioreabsorção
Blendas poliméricas
Poli (ácido lático)
Policaprolactona
Stents
Resumo em português
O Poli (ácido lático), PLA, e a Policaprolactona, PCL, são dois poliésteres termoplásticos alifáticos, conhecidos por suas capacidades de biodegradabilidade e bioreabsoção e, nos últimos anos, têm sido amplamente estudados como alternativas aos metais em bioimplantes. Por terem características mecânicas distintas, muitas vezes estes materiais são utilizados em blendas poliméricas, visando obter uma combinação construtiva entre tais propriedades; o PLA é mais rígido, tem maior resistência à tração, contudo é frágil; o PCL tem menor rigidez, contudo apresenta maior tenacidade, além de ser extremamente dúctil. A combinação destas propriedades em uma blenda torna a dupla PLA/PCL especialmente atraente à utilização em stents coronarianos, no qual o uso do PLA como único componente do stent pode causar complicações ao paciente, devido à necessidade de aquecimento do material acima de sua temperatura de transição vítrea (ao redor dos 60°C) para que ele possa ser inflado sem risco de uma catastrófica falha. Entretanto, tal aquecimento pode causar necrose dos tecidos coronarianos. Assim sendo, a inclusão do PCL na blenda tem como principal objetivo diminuir a temperatura de transição vítrea do conjunto do PLA. Este estudo teve como principal foco a análise de como o acréscimo de PCL e de dois diferentes tipos de compatibilizantes impactou no comportamento térmico e mecânico das blendas. Para tal, testes dos vinte tipos de blendas desenvolvidas foram submetidos a análises de DSC, DMTA e a ensaios de tração e impacto. Os últimos dois são de fundamental importância, pois o PLA tem pouca ductilidade e resistência ao impacto. Além desses testes, foram efetuadas também análises MEV, com intuito de verificar as modificações morfológicas das blendas ao adicionar-se tanto os compatibilizantes, quanto PCL às formulações. Ensaios espectroscópicos na região do infravermelho também foram conduzidos, a fim de analisar-se, além das estruturas químicas dos componentes da blenda, as interações entre eles e as modificações espectrais causadas por ela. Testes preliminares, como o GPC e a termogravimetria, também estão presentes. Com isso foi possível, além de fazer a determinação da massa molar dos componentes da blenda, ter acesso a dados acerca da degradação térmica dos polímeros utilizados. Ademais, a fim de analisar-se preliminarmente o potencial das blendas desenvolvidas como biomaterial, foram efetuados testes de Citotoxidade em formulações selecionadas. Como resultado da intensa investigação sobre as propriedades das blendas PLA/PCL, compatibilizadas ou não, foi verificado grande aumento de ductilidade nas formulações, sem perda apreciável de resistência mecânica. Em muitas das blendas, houve também expressivo aumento na tenacidade. Em contrapartida, não foram verificadas alterações significativas no perfil térmico das amostras, conforme DMTA e DSC.
Título em inglês
Study of the mechanical properties and biocompatibility of compatibilized or not compatibilized PLA/PCL blends
Palavras-chave em inglês
Bioimplants
Bioresorption
Polycaprolactone
Polylactide
Polymer blends
Stents
Resumo em inglês
The Polylactide, PLA, and the Polycaprolactone, PCL, are two thermoplastic aliphatic polyesters, known for their biodegradability and bioresorption abilities and, in the latest years, they have been extensively studied as alternatives to metals in bioimplants. Since they have distinct mechanical properties, these materials are many times used in polymeric blends, in order to obtain a constructive combination of the mechanical properties; the Polylactide is more rigid and has better tensile resistance, however it is brittle; on the other hand, the Polycaprolactone has lower rigidity, but it has better toughness, in addition to its great ductility. The combination of these properties in a blend makes the PLA/PCL configuration especially attractive to the use in coronary stents, on which the use of the PLA as only component may cause serious complications to the patient, due to its need to be warmed above its glass transition temperature (around 60°C) in order to be inflated without the risk of any catastrophic failure. However, this heating might cause necrosis of the coronary tissue. The inclusion of the PCL on the blend has, as a main goal, the objective of, in addition to lowering the glass transition temperature on the aggregate, is to allow the expansion of the material with no risk of failure. This study focused on how the addition of PCL and two different kinds of compatibilizers alters the thermal and mechanical behavior of the blends. To do so, tests were performed on the twenty types of blends developed, e.g. DSC, DMTA, tensile and impact tests. The latter two are of critical importance, because the Polylactide has little toughness and ductility. Furthermore, SEM was also performed in order to verify the morphological changes caused by increasing the PCL concentration on the blends, as well as the addition of the compatibilizers. Infrared spectroscopic analysis was also conducted on the blends, thus the chemical structures of the main components of the blends could be assessed, as well as the interactions and the spectral changes caused by it. Preliminary tests, for example, GPC and thermogravimetry were also conducted. With this data, it was possible to determine the molar mass of the blends components and assess the thermal degradation profile of the materials used. Moreover, preliminary tests were conducted in order to determine the potential some selected blends have as biomaterials. As the result of this deep research on the PLA/PCL blends properties, compatibilized or not, it was possible to achieve relevant increase in the ductility and toughness of the formulations, with no significant loss in terms of mechanical resistance. On the other hand, no significant changes on the thermal profile of the blends were observed, according to DMTA and DSC tests.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Data de Publicação
2015-04-09
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.