• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.18.2012.tde-06062012-112247
Documento
Autor
Nome completo
Alexandre Bozolan dos Santos
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2012
Orientador
Banca examinadora
Romero, Murilo Araujo (Presidente)
Fontana, Eduardo
Matos, Christiano José Santiago de
Ribeiro, Sidney José Lima
Sodré Junior, Arismar Cerqueira
Título em português
Dispositivos baseados no preenchimento de fibras de cristal fotônico por líquidos e materiais nanoestruturados
Palavras-chave em português
Fibra de cristal fotônico
Fibra microestruturada
Fluorescência
Óptica não-linear
Sensoriamento
Supercontínuo
Resumo em português
Esta tese descreve a demonstração experimental de dispositivos baseados em fibras de cristal fotônico (PCFs), que aproveitam a flexibilidade estrutural oferecida pela matriz de capilares que compõe a seção reta da fibra, de forma a preencher estes capilares com líquidos e materiais nanoestruturados. Para o caso de materiais nanoestruturados, uma vez preenchida a fibra, os materiais nela inseridos interagem eficientemente com a luz guiada. Essa arquitetura diferenciada em relação às fibras ópticas convencionais abre novas perspectivas no desenvolvimento de aplicações como óptica não-linear e sensoriamento. PCFs de núcleo líquido, por outro lado, impõe dificuldades para a implementação de dispositivos práticos, devido às altas taxas de evaporação dos líquidos inseridos. Por esta razão, foi desenvolvida uma nova técnica para vedar seletivamente ambas as faces externas do núcleo líquido de uma PCF, utilizando um polímero curável. Estes tampões poliméricos evitam a evaporação, causando um impacto mínimo no guiamento da luz, tornando o dispositivo usável por semanas. Esta nova técnica de vedação foi empregada em um experimento para a geração de supercontínuo em uma PCF com núcleo de água destilada, proporcionando uma estabilidade de pelo menos 1 hora. Combinando líquidos e materiais nanoestruturados, foi também foi desenvolvido um sensor de temperatura baseado no preenchimento do núcleo de uma PCF por uma amostra coloidal de nanopartículas semicondutoras de CdSe/ZnS, dispersas em óleo mineral. O espectro de luminescência destes pontos quânticos coloidais é fortemente dependente da temperatura e os resultados obtidos mostraram que a grande interação entre a luz e o colóide, aliada a geometria da fibra, proporcionando uma sensibilidade ~5,5 vezes maior que a apresentada por uma rede de Bragg escrita em uma fibra óptica padrão, com boa relação sinal-ruído.
Título em inglês
Devices based on the filling of photonic crystal fibers by liquids and nanostructured materials
Palavras-chave em inglês
Luminescence
Microstructured fiber
Non-linear optics
Optical sensing
Photonic crystal fiber
Supercontinuum generation
Resumo em inglês
This thesis describes the experimental demonstration of devices based on photonic crystal fibers (PCFs). PCFs are optical fibers whose core is surrounded by a regular matrix of holes, which runs longitudinally across its length. This singular configuration allows the insertion of liquids and nanostructured material into the fiber. Nanostructured materials embedded inside the fiber efficiently interact with the guided light, opening up possibilities of novel applications regarding the fields of non-linear optics, as well as optical sensing. On the other hand, liquid-core PCFs suffer from some disadvantages concerning practical device applications, on account of the high evaporation of the inserted liquids. In order to address this issue, we developed a novel technique to selectively seal the external faces of a liquid-core PCF, by using a polymer plug. These polymer plugs avoid evaporation while causing a minimum impact on the light guiding characteristics of the PCF. This novel sealing technique was employed in a supercontinuum generation experiment, by using a PCF whose core was water-filled. A temporal stability of at least one-hour on the resulting spectrum was achieved. Combining the above techniques, we also developed a temperature sensor based on the core-filling of a PCF by a colloidal ensemble of CdSe/ZnS semiconductor nanoparticles dispersed in mineral oil. Those colloidal quantum-dots display a luminescence spectrum which is strongly dependent on temperature and the experimental results indicated that the greater interaction between the guided light and the colloidal sample, provided by the fiber geometry, allowed a sensitivity which is approximately 5.5 times than possible with a conventional Bragg grating, while keeping a satisfactory signal-to-noise ratio.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
Alexandre.pdf (7.30 Mbytes)
Data de Publicação
2012-06-26
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.