Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2018.tde-05092018-171824
Document
Auteur
Nom complet
Leandro Rosa Dias
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2018
Directeur
Jury
Vieira Júnior, José Carlos de Melo (Président)
Leão, Fábio Bertequini
Moura, Fabrício Augusto Matheus
Titre en portugais
Análise da influência de elevados níveis de geração fotovoltaica na operação das redes reticuladas de distribuição de energia elétrica
Mots-clés en portugais
Fluxo reverso de potência
Geração fotovoltaica
Gerador distribuído
Protetor de rede
Rede reticulada
Resumé en portugais
As instalações de geradores distribuídos têm sido impulsionadas pela necessidade da diversificação da matriz energética nos países, por fatores ambientais e por revelar benefícios aos sistemas elétricos. No Brasil, estas conexões têm apresentado um crescimento bastante significativo nos últimos anos, devido às novas regulamentações estabelecidas pela ANEEL. Entretanto, alterações no sistema elétrico em grandes escalas acarretam consequências à operação segura, confiável e de qualidade do mesmo. Neste contexto, ainda há poucos trabalhos que analisam tais problemas em sistemas reticulados de distribuição de energia elétrica e, com base nisso, o presente trabalho visa avaliar os impactos que elevados níveis de geração fotovoltaica podem acarretar aos níveis de tensões nodais, às perdas técnicas e também à proteção destes sistemas, adotando como referência uma rede reticulada real de 81 barras e a rede do IEEE 390 barras. Uma vez que tais condições são avaliadas têm-se as análises de adição de funções de proteção (direcional de potência, direcional de sobrecorrente, subtensão e desbalanço de tensão) a fim de buscar alternativas para que os protetores de rede não se sensibilizem para fluxos reversos de potência provenientes dos geradores distribuídos e, assim, estes se limitem a atuarem para distúrbios no lado de média tensão. Para tanto, as simulações foram realizadas no programa OpenDSS e os resultados mostraram que a função de desbalanço de tensão é a que se apresenta com maior potencial para ser aplicada na prática, uma vez que foi possível minimizar o número de atuações dos protetores de rede devido aos geradores distribuídos.
Titre en anglais
Analysis of the influence of high levels of photovoltaic generation in the operation of low-voltage secondary distribution networks
Mots-clés en anglais
Distributed generation
Grid network
Network protector
Photovoltaic generation
Reverse power flow
Spot network
Resumé en anglais
The installation of distributed generators have been boosted by the need to diversify the energy matrix in the countries, by environmental issues and by revealing benefits to the electrical systems. In Brazil, these connections have shown a very significant growth in the last years, due to the new regulations established by the National Agency of Electric Energy. However, large-scale changes in the electrical system lead to consequences for its safe, reliable and well-qualified operation. In this context, there are still few studies that analyze such problems in low-voltage secondary distribution networks, and based on this, the present work aims to analyze the performance of these systems based an actual Brazilian 81-nodes low-voltage secondary network and on the IEEE 390-nodes system. The objective is to evaluate the impacts of high levels of distributed generation on the power quality and protection of the grid. Once such conditions are evaluated, some protection functions are considered (directional power, directional overcurrent, undervoltage and voltage unbalance) with the purpose of finding alternatives so that the network protectors are not sensitized to reverse power flows from the distributed generators and, thus, they only trip for disturbances an the medium voltage side. Therefore, the simulations were performed in the OpenDSS software and the results showed that the voltage unbalance protection function was the one with the highest potential to be applied in practice, since it was possible to minimize the reverse power flow due to distributed generators.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Leandro.pdf (9.47 Mbytes)
Date de Publication
2018-09-10
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.