Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2017.tde-02082017-164542
Documento
Autor
Nombre completo
Marina Silva Camillo de Carvalho
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2017
Director
Tribunal
Machado, Ricardo Quadros (Presidente)
Coelho, Ernane Antônio Alves
Villalva, Marcelo Gradella
Título en portugués
Análise de técnicas de detecção de ilhamento ativas em sistemas de geração distribuída baseados em inversores fonte de tensão
Palabras clave en portugués
Conversor CC-CA
Detecção de ilhamento
Fontes alternativas
Geração distribuída
Resumen en portugués
A abordagem principal desse trabalho é o estudo de técnicas anti-ilhamento ativas com realimentação positiva em um sistema de Geração Distribuída (GD) composto por um Inversor Fonte de Tensão (VSI,do inglês Voltage Source Inverter) e com cargas locais conectadas em paralelo. Na literatura são encontrados dois grupos de técnicas empregadas como proteção anti-ilhamento: as ativas e as passivas. Os métodos de detecção de ilhamento ativos são utilizados, pois possuem menores zonas de não detecção em comparação às técnicas passivas, porém injetam distúrbios contínuos no sistema de GD. Esses distúrbios degradam a qualidade de energia elétrica fornecida pelo conversor eletrônico. Nesse contexto, como escopo dessa dissertação, é realizado o estudo da estrutura de controle empregada no sistema de GD conectado com a rede de distribuição, com o intuito de avaliar o funcionamento do gerenciamento de tensão e de potência ativa e reativa. E em seguida, são discutidas técnicas de detecção de ilhamento ativas em frequência e tensão, ambas, com realimentação positiva e ganho fixo com o objetivo de investigar o desempenho das mesmas em relação ao tempo de detecção e a injeção de distúrbios no sistema de controle da GD. A partir dessa análise, são desenvolvidas técnicas anti-ilhamento com intuito de reduzir a injeção de distúrbios em diferentes pontos de operação da GD e garantir uma eficiência semelhante aos métodos tradicionais em casos de difícil detecção. Essas técnicas são baseadas na implementação do cálculo de um ganho com realimentação positiva variável inversamente proporcional a variação de potência ativa ou reativa entregue a rede. Para validação das propostas presentes nesta dissertação, são obtidos resultados em simulações computacionais e, posteriormente são adquiridos resultados práticos através de uma bancada experimental compatível com o sistema de GD simulado.
Título en inglés
Analysis of active islanding detection techniques in distributed generation systems based on voltage source inverters
Palabras clave en inglés
Alternative sources
DC-AC converter
Distributed generation
Islanding detection
Resumen en inglés
The main approach of this thesis is the study of active anti-islanding techniques with positive feedback in a Distributed Generation (DG) system composed by a Voltage Source Inverter (VSI) and local loads. In literature two groups of techniques are used as anti-island protection: the active and the passive techniques. The active islanding detection methods are preferably used because of the smaller non-detection zones compared to passive techniques, however they inject continuous disturbances in the DG system, reducing the power quality provided by the VSI. In this context, as the scope of this dissertation, it is firstly carried out the study of control structures employed in grid-tied distribution system, to evaluate the operation of the voltage control loops, and the active-and reactive power managements. Additionally, we discuss active islanding detection techniques in frequency and voltage with positive feedback and constant gain, based on the classical, with the objective of investigating their performance in relation to the detection time and the injection of disturbances in the DG system. From this analysis, antiislanding techniques are developed to guarantee efficiency similar to the traditional methods in cases of small-power flow through the grid and minimize disturbances. These techniques are based on the calculation of the positive feedback variable gain inversely proportional to the deviation of active or reactive power delivered or absorbed from the grid. To validate this proposal, the results are obtained through computational simulations and experimental analysis, as well.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Marina.pdf (10.94 Mbytes)
Fecha de Publicación
2017-08-08
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.