• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2008.tde-12022009-091751
Document
Auteur
Nom complet
Cássio Avelino Adorni
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2008
Directeur
Jury
Gonzaga, Adilson (Président)
Paiva, Maria Stela Veludo de
Pereira, Aledir Silveira
Titre en portugais
Metodologia para automação de inspeção visual de bolsas para coleta de sangue
Mots-clés en portugais
Bolsa para coleta de sangue
Inspeção visual
Transformada Wavelet
Wavelet Haar
Resumé en portugais
As bolsas para coleta de sangue necessitam cuidados técnicos que assegurem sua esterilidade biológica durante o processo de fabricação até a entrega do produto final. As bolsas para coleta de sangue não devem conter qualquer tipo de resíduo, para que o seu uso ou conteúdo não seja comprometido causando diversos transtornos. É preciso eliminar o risco de contaminação; no entanto muitas empresas fazem a inspeção de bolsas para coleta de sangue visualmente, a olho nu, por funcionários treinados no uso de equipamento simples, o qual não pode garantir que todas as bolsas estejam livres de resíduos, por depender do fator humano. Para assegurar a esterilização das bolsas comercializadas, este trabalho propõe uma metodologia para automação de um sistema de visão computacional baseado em conjunto de técnica de extração de características de imagens e reconhecimento de padrões para detectar resíduos em imagens de bolsas para coleta de sangue durante o processo de fabricação, e assim, melhorar a qualidade das bolsas comercializadas. Os resíduos encontrados nas imagens capturadas se apresentam como componentes de alta freqüência. A metodologia proposta utiliza a Transformada Wavelet (Wavelet de Haar) em dois níveis de decomposição, como filtro passa - alta para destacar as altas freqüências, e assim detectar a existência de resíduos nas imagens capturadas. Os resultados obtidos com a inspeção visual manual realizada em bolsas para coleta de sangue, mostram que existem resultados divergentes na análise de uma mesma bolsa, o que reforça a necessidade de automatização dessa tarefa para que sejam obtidos resultados mais uniformes com padrões definidos, e dessa maneira melhorar a qualidade das bolsas comercializadas para coleta de sangue.
Titre en anglais
Methodology to automation visual inspection for blood bags
Mots-clés en anglais
Blood bag
Visual inspection
Wavelet of Haar
Wavelet transform
Resumé en anglais
The blood bags require technician attention to assure its biological sterility in the process of manufacture and in the final product. The blood bags must not contain any type of waste, so that its use or content is not compromised causing various disorders; it is necessary to eliminate any contamination risk; however many companies perform a visually inspection of the blood bags, by naked eye, by trained employees in the use of a simple equipment, which cannot guarantee that all the bags are residue-free because depending on the human factor. The residues showed on the pictures were characterized as high frequency components. So the proposed methodology applies two levels decomposition of Haar´s Wavelet as high pass filter to evidence high frequencies, and to evidence the residues at the pictures and to evidence the existence of residues on the captured pictures. To assure the sterilization of the commercialized blood bags, this work propose a methodology of an automated computational system based in a group of techniques of image characteristics extraction and recognition patterns to detect residues in blood bag images in the process of manufacture, in order to improve the quality of the commercialized blood bags.This technique is used as high-pass filter, to detach the high frequencies, using a Haar-wavelet in two decomposition levels. The results obtained with the manual visual inspection indicate that were found divergent results in the analysis of the same blood bag, which reinforces the necessity of the automation of this task in order to obtain more uniform results with defined standards.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Cassio.pdf (4.12 Mbytes)
Date de Publication
2009-02-16
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.