Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2008.tde-12022009-091751
Document
Author
Full name
Cássio Avelino Adorni
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2008
Supervisor
Committee
Gonzaga, Adilson (President)
Paiva, Maria Stela Veludo de
Pereira, Aledir Silveira
Title in Portuguese
Metodologia para automação de inspeção visual de bolsas para coleta de sangue
Keywords in Portuguese
Bolsa para coleta de sangue
Inspeção visual
Transformada Wavelet
Wavelet Haar
Abstract in Portuguese
As bolsas para coleta de sangue necessitam cuidados técnicos que assegurem sua esterilidade biológica durante o processo de fabricação até a entrega do produto final. As bolsas para coleta de sangue não devem conter qualquer tipo de resíduo, para que o seu uso ou conteúdo não seja comprometido causando diversos transtornos. É preciso eliminar o risco de contaminação; no entanto muitas empresas fazem a inspeção de bolsas para coleta de sangue visualmente, a olho nu, por funcionários treinados no uso de equipamento simples, o qual não pode garantir que todas as bolsas estejam livres de resíduos, por depender do fator humano. Para assegurar a esterilização das bolsas comercializadas, este trabalho propõe uma metodologia para automação de um sistema de visão computacional baseado em conjunto de técnica de extração de características de imagens e reconhecimento de padrões para detectar resíduos em imagens de bolsas para coleta de sangue durante o processo de fabricação, e assim, melhorar a qualidade das bolsas comercializadas. Os resíduos encontrados nas imagens capturadas se apresentam como componentes de alta freqüência. A metodologia proposta utiliza a Transformada Wavelet (Wavelet de Haar) em dois níveis de decomposição, como filtro passa - alta para destacar as altas freqüências, e assim detectar a existência de resíduos nas imagens capturadas. Os resultados obtidos com a inspeção visual manual realizada em bolsas para coleta de sangue, mostram que existem resultados divergentes na análise de uma mesma bolsa, o que reforça a necessidade de automatização dessa tarefa para que sejam obtidos resultados mais uniformes com padrões definidos, e dessa maneira melhorar a qualidade das bolsas comercializadas para coleta de sangue.
Title in English
Methodology to automation visual inspection for blood bags
Keywords in English
Blood bag
Visual inspection
Wavelet of Haar
Wavelet transform
Abstract in English
The blood bags require technician attention to assure its biological sterility in the process of manufacture and in the final product. The blood bags must not contain any type of waste, so that its use or content is not compromised causing various disorders; it is necessary to eliminate any contamination risk; however many companies perform a visually inspection of the blood bags, by naked eye, by trained employees in the use of a simple equipment, which cannot guarantee that all the bags are residue-free because depending on the human factor. The residues showed on the pictures were characterized as high frequency components. So the proposed methodology applies two levels decomposition of Haar´s Wavelet as high pass filter to evidence high frequencies, and to evidence the residues at the pictures and to evidence the existence of residues on the captured pictures. To assure the sterilization of the commercialized blood bags, this work propose a methodology of an automated computational system based in a group of techniques of image characteristics extraction and recognition patterns to detect residues in blood bag images in the process of manufacture, in order to improve the quality of the commercialized blood bags.This technique is used as high-pass filter, to detach the high frequencies, using a Haar-wavelet in two decomposition levels. The results obtained with the manual visual inspection indicate that were found divergent results in the analysis of the same blood bag, which reinforces the necessity of the automation of this task in order to obtain more uniform results with defined standards.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Cassio.pdf (4.12 Mbytes)
Publishing Date
2009-02-16
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.