Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2009.tde-11012010-104228
Documento
Autor
Nombre completo
Paulo Domingues de Oliveira Júnior
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2009
Director
Tribunal
Vieira, Marcelo Andrade da Costa (Presidente)
Escarpinati, Mauricio Cunha
Poletti, Martin Eduardo
Título en portugués
Esquema computacional para avaliação automática de parâmetros de qualidade de equipamentos mamográficos
Palabras clave en portugués
Curva sensitométrica
Densidade espectral de ruído
Eficiência de detecção quântica
Função de transferência de modulação
Mamografia - controle de qualidade
Resumen en portugués
Este trabalho tem como objetivo o desenvolvimento de um conjunto de procedimentos de avaliação da qualidade de equipamentos mamográficos a partir do processamento de imagens digitais obtidas com a exposição radiográfica de objetos de testes (phantoms) padronizados. O sistema desenvolvido permite a avaliação de diversos parâmetros físicos de qualidade da imagem radiográfica com simplicidade e rapidez, sem abrir mão da precisão, com o mínimo tempo e uso dos equipamentos. Os principais parâmetros avaliados relacionados à qualidade de um sistema de imagem são: a resolução espacial - pela medida da função de transferência de modulação (MTF) - o contraste - medido pela curva sensitométrica e o ruído - pela medida da densidade espectral de ruído (NPS). Dessa forma, o sistema desenvolvido atende às recomendações do ICRU (International Commission on Radiation Units and Measurements), que trata das diretrizes para controle de qualidade de imagens radiográficas em todo o mundo. A partir da medida desses três parâmetros de qualidade é possível também aferir a eficiência de detecção quântica (DQE) do sistema de imagem mamográfica, que permite uma avaliação completa da qualidade da imagem em função da dose recebida pelo paciente. Os resultados obtidos comprovam a possibilidade da aplicação prática do sistema desenvolvido, o qual proporciona uma avaliação completa da qualidade da imagem formada pelo equipamento. Todos os resultados apresentaram baixa estimativa de erro, fundamentados pela análise da incerteza nos processos de medida. Além disso, a avaliação por meio do DQE permitiu realizar uma comparação entre os sistemas mamográficos envolvidos nessa pesquisa. Assim, com base nesses resultados é possível afirmar que o sistema computacional desenvolvido pode desempenhar um papel fundamental na avaliação da qualidade em sistemas de imagens mamográficas.
Título en inglés
Computational scheme for automatic evaluation of mammography equipments quality parameters
Palabras clave en inglés
Detective quantum efficiency
H&D curve
Mammography - quality assurance
Modulation transfer function
Noise power spectrum
Resumen en inglés
The aim of this work is to develop a set of procedures for quality assurance of mammographic equipment by the digital image processing of radiographic images of standard test objects (phantoms) acquired by the radiographic equipment. It allows the evaluation of several physical parameters of the radiographic image quality by a simple and quick procedure, with good accuracy, using the equipment the shortest time as possible. The main evaluated parameters related to the quality of an imaging system are: spatial resolution - by measuring the modulation transfer function (MTF) - image contrast - by the measurement of the H&D curve and noise - evaluated by the noise power spectrum (NPS). Thus, it attends the recommendations of the ICRU (International Commission on Radiation Units and Measurements), which deals as the guidelines for quality assurance of radiographic images all over the world. Through these quality parameters is possible to measure the detective quantum efficiency (DQE) of any mammographic system, which allows a full evaluation of the image quality related to the dose absorbed by the patient. The results confirm the possibility of the practical application of the developed system, which provides a full evaluation of the image quality, acquired by the mammographic equipment. All results showed low error estimation, substantiated by the analysis of the uncertainty in measurements procedures. Moreover, the evaluation through the DQE allowed to perform a comparison of mammography systems involved in this research. Thus, based on these results, it is possible to confirm that its system can perform a fundamental part of the quality assurance in mammographic images system.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.