• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2010.tde-10082010-135546
Documento
Autor
Nombre completo
Débora Regina Malvesi Stemberg
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2010
Director
Tribunal
Schiabel, Homero (Presidente)
Furquim, Tânia Aparecida Correia
Martinelli, Simone Elias
Título en portugués
Desenvolvimento de simulador mamográfico para avaliação de esquemas CAD
Palabras clave en portugués
Esquemas CAD
Mamografia
Processamento de imagens mamográficas
Simulador radiográfico
Resumen en portugués
Visando a um melhor desempenho na avaliação de imagens mamográficas, diversos trabalhos utilizando técnicas de processamento de imagem vêm sendo desenvolvidos como parte de esquemas computacionais que auxiliam o diagnóstico, denominados de esquemas CAD. Entretanto, um dos maiores desafios no desenvolvimento destes sistemas está relacionado com a avaliação de seu desempenho, que pode apresentar inconsistências, como impossibilidade de comparação dos resultados devido à dificuldade de se obter bancos de imagens amplos, comuns e confiáveis, que apresentem características de aquisição variadas atendendo aos requisitos específicos da técnica. Este trabalho tem por objetivo auxiliar nesse campo, apresentando um protótipo de simulador radiográfico de mama que possibilite gerar imagens que se assemelhem às de uma mamografia real através ainda de uma distribuição aleatória das estruturas de interesse simuladas. Isso permite a aquisição de um grande conjunto de imagens, por diferentes formas e condições, tornando possível testar e avaliar com maior precisão o desempenho de esquemas CAD destinados à mamografia. Tem a virtude de dispensar a validação dos resultados apontados pelo esquema com base no laudo do especialista, visto que é possível saber previamente quais são e quantas são as estruturas presentes em cada imagem, bem como a localização exata de cada uma delas. Portanto, torna-se possível assegurar com confiança a eficácia e viabilidade do esquema CAD testado, tanto em relação ao resultado apresentado pelo sistema quanto em relação à minimização de erros sistemáticos, dada a aleatoriedade da distribuição das estruturas-alvo da avaliação, como ocorre no exame real.
Título en inglés
Development of a breast Phantom for CAD schemes evaluation
Palabras clave en inglés
CAD schemes
Mammographic images processing
Mammography
Phantom
Resumen en inglés
In order to obtain a better performance in the evaluation of mammographic images, several studies using image processing techniques have been developed as part of computer aided diagnosis, known as CAD systems. However, one of the main challenges in the development of such schemes is the performance evaluation, which may present problems, as such as difficulty in comparing results due to the inability to obtain large and common databases with wide-ranging characteristics of image acquisition. This work has the purpose of helping in this field, by presenting a breast phantom to allow obtaining images closer to those from actual mammography due to a random distribution of simulated interest structures. This provides to get a large images set, obtained from different conditions, and it allows to evaluate more accurately the performance of mammography CAD schemes. The use of this phantom has also the advantage of validating the scheme results without using the radiological report, since it provides the exact knowledge of the number and characteristics of the structures present in the image, as well as their positioning. Therefore, the efficacy and feasibility of a CAD scheme under test can be assured, regarding the results and also by the minimization of systematic errors due to the random distribution of the structures of clinical interest, similarly to the actual exam.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Debora.pdf (3.33 Mbytes)
Fecha de Publicación
2010-09-17
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.