• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2008.tde-04072008-094950
Documento
Autor
Nombre completo
Luís Carlos Hamula Campos
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2008
Director
Tribunal
Schiabel, Homero (Presidente)
Medeiros, Regina Bitelli
Rodrigues, Evandro Luis Linhari
Título en portugués
Avaliações de qualidade aplicadas na comparação de sistemas mamográficos digitais e convencionais
Palabras clave en portugués
Mamografia convencional
Radiologia digital
Simulador ACR
Resumen en portugués
Este trabalho tem por objetivo avaliar o desempenho dos equipamentos de radilogia digital, especificamente, mamógrafo de campo total e mamógrafos convencionais no que se refere à detecção de sinais e em termos da geometria da exposição. O trabalho se desenvolve a partir da formação de um conjunto de imagens mamográficas do simulador ACR modelo 156; este conjunto é composto por imagens mamográficas de equipamentos convencionais e digitais de campo total e imagens obtidas por um simulador radiográfico incorporado a um pacote computacional que fornece informações características de equipamentos radiológicos quanto ao desempenho do sistema em termos da geometria de exposição como ponto focal, limites de resolução e ruído aleatório produzido. A partir dos resultados das interpretações das imagens do simulador ACR pelos observadores, determina-se o índice de acertos; paralelamente analisam-se os dados relativos à geometria da exposição.
Título en inglés
Quality assessment applied to the comparison as digital and conventional mammographics systems
Palabras clave en inglés
ACR phantom
Conventional mammograph
Digital mammography
Resumen en inglés
This work is aimed at evaluating the performance of digital radiology especially full digital mammograph and conventional mammograph in order to detect signals send in terms of geometry of the exposition. The work is developed from the formation of a pool of mammographic images of the ACR Phantom 156; this bank is formed by mammograph images of both conventional and full field digital equipments and images got by a radiographic test gadget linked to a software package that provides typical information of radiologic equipments concerning the system's performance regarding geometric of exposition like focal spot, margins of resolution and aleatory noise. From the results of the interpretation of the ACR simulator's images by the observers, then, we are able to determine what is right, at the same time to analyze the data related to the geometry of exposition.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
LuisCarlos.pdf (2.56 Mbytes)
Fecha de Publicación
2008-07-04
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.