• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Thèse de Doctorat
DOI
https://doi.org/10.11606/T.18.2014.tde-09022015-113119
Document
Auteur
Nom complet
Reinaldo Cesar
Adresse Mail
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2014
Directeur
Jury
Rollo, João Manuel Domingos de Almeida (Président)
Bonagamba, Tito José
Fortulan, Carlos Alberto
Gaspar, Ana Maria Minarelli
Kunkel, Maria Elizete
Titre en portugais
Avaliação da microarquitetura e biomecânica de ossos trabeculares normais, osteopênicos e osteoporóticos de vértebras humanas por técnicas de ensaios mecânicos, microtomografia de raios-X e homogeneização assintótica
Mots-clés en portugais
Ensaios mecânicos
Homogeneização assintótica
Microtomografia de raios-X
Ossos trabeculares de vértebras humanas
Osteoporose
Resumé en portugais
Avaliação da "qualidade" da microarquitetura óssea contribui na prevenção e risco de fraturas associado a osteoporose. Amostras de ossos trabeculares de corpos vertebrais da região T12, L1 e L4 de 30 de indivíduos (cadáveres humanos), classificados pela técnica de ultrassonometria de calcâneo como normais, osteopênicos e osteoporóticos foram utilizadas. Os parâmetros histomorfométricos, físicos e mecânicos da microarquitetura analisados pela técnica de microtomografia de raios-X, ensaios mecânicos de compressão axial e nanoindentação. Baseado nestes parâmetros, constantes elásticas efetivas globais foram obtidas pela técnica homogeneização assintótica para estrutura tipo-placa. Teste ANOVA apresentou diferenças, muito e extremamente significativas para densidade linear estrutural (p = 0,017), grau de anisotropia (p = 0,042), auto valor (p = 0,045), número de Euler (p = 0,016), idade (p = 0,009), separação trabecular (p = 0,009), densidade de conectividade (p = 0,006), módulo de elasticidade (p = 0,001), tensão máxima no limite de resistência a fratura (0,001), índice de qualidade óssea do calcâneo (p = 0,0001), fração de volume ósseo (p = 0,0001), espessura trabecular (p = 0,0002), dimensão fractal (p = 0,0002), momento de inércia polar médio (p = 0,00005), excentricidade (p = 0,0002), fração de porosidade (p = 0,0001) e densidade mineral óssea aparente (p = 0,00005) entre os grupos. O teste de Spearman identificou correlação moderada, alta e muito alta dos valores da tensão máxima no limite de resistência a fratura com os parâmetros de idade (r = -0,684), fração de volume ósseo (r = 0,762), fator de forma trabecular (r = -0,754), espessura trabecular (r = 0,675), densidade linear trabecular (r = 0,622), autos valores (r = -0,615), dimensão fractal (r = 0,855), momento de inércia polar médio (r = 0,816), excentricidade (r = -0,569) e fração de porosidade (r = -0,762). Estes parâmetros são indicadores da qualidade da microarquitetura óssea trabecular e risco de fratura associado a osteoporose.
Titre en anglais
Evaluation of microarchitecture and biomechanics of normal, osteopenic and osteoporotic trabecular bones from human vertebrae by mechanical tests, X-ray microtomography and asymptotic homogenization techniques
Mots-clés en anglais
Asymptotic homogenization
Human vertebrae trabecular bones
Mechanical testing
Osteoporosis
X-ray microtomography
Resumé en anglais
Evaluation of the "quality" of bone microarchitecture can contribute to the prevention and risk of fractures associated with osteoporosis. Samples of trabecular bone from the vertebral regions T12, L1 and L4 from the bodies of 30 individuals (human cadavers), classified by ultrasonometry technique calcaneus as normal, osteopenic and osteoporotic were used. The histomorphometric, physical and mechanical parameters of the microarchitecture were analyzed by X-ray microtomography technique, mechanical tests of axial compression and nanoindentation. Based on these parameters, globally effective elastic constants were obtained by asymptotic homogenization technique for type-plate structure. ANOVA test showed differences that were very and extremely significant for the following: structural linear density (p = 0.017) anisotropy (p = 0.042), auto value (p = 0.045), Euler number (p = 0.016), age (p = 0.009), trabecular separation (p = 0.009), connectivity density (p = 0.006), elastic modulus (p = 0.001), maximum stress fracture strength limit (0.001), bone quality score of the calcaneus (p = 0.0001), bone volume fraction (p = 0.0001), trabecular thickness (p = 0.0002), fractal dimension (p = 0.0002), mean polar moment of inertia (p = 0.00005), eccentricity (p = 0.0002), porosity fraction (p = 0.0001) and apparent bone mineral density (p = 0.00005) between groups. The Spearman test identified moderate correlation, high and very high values of maximum stress fracture resistance limit for the following parameters: age (r = -0.684), bone volume fraction (r = 0.762), trabecular bone pattern factor (r = -0.754), trabecular thickness (r = 0.675), trabecular linear density (r = 0.622), auto value (r = -0.615), fractal dimension (r = 0.855), mean polar moment of inertia (r = 0.816), eccentricity (r = -0.569) and porosity fraction (r = -0.762). These parameters are quality indicators of the microarchitecture of trabecular bone and fracture risk associated with osteoporosis.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.
Date de Publication
2015-02-19
 
AVERTISSEMENT: Apprenez ce que sont des œvres dérivées cliquant ici.
Tous droits de la thèse/dissertation appartiennent aux auteurs
CeTI-SC/STI
Bibliothèque Numérique de Thèses et Mémoires de l'USP. Copyright © 2001-2024. Tous droits réservés.