Título em português
Desenvolvimento de sistema LIBS-LIF
Palavras-chave em português
Espectroscopia
Instrumentação
Laser de Diodo de Cavidade Estendida
LIBS-LIF
Resumo em português
A espectroscopia de emissão atômica de plasma induzido por laser (LIBS, do inglês Laser Induced Breakdown Spectroscopy) é uma técnica multi-elementar que tem ganhado destaque recentemente devido à sua facilidade de uso em diversas aplicações. Entretanto, o limite de detecção da técnica é alto para alguns elementos se comparada com outras técnicas (e.g. ICP). Assim, o objetivo deste trabalho é aperfeiçoar a sensibilidade de um sistema LIBS na configuração de pulso único, através da integração com a técnica de fluorescência induzida por laser (LIF). Isso é feito por meio da inserção de um laser com um comprimento de onda em uma transição ressonante do elemento cuja intensidade de emissão deseja-se ter elevada, visando a redução dos efeitos de matriz das amostras. Para este fim, foram desenvolvidos um laser de diodo contínuo de cavidade estendida e sua eletrônica de controle, almejando um sistema robusto, estável em frequência, com baixo ruído espectral e resistente a estresses mecânicos, elétricos e térmicos. Os mesmos foram integrados a um sistema LIBS para ser feita a comprovação da eficiência da técnica LIBS-LIF.
Título em inglês
Development of a LIBS-LIF system
Palavras-chave em inglês
Extended Cavity Diode Laser
Instrumentation
LIBS-LIF
Spectroscopy
Resumo em inglês
The laser-induced breakdown plasma spectroscopy (LIBS) is a multi-elemental technique that has been gainning prominence recently due to its easy usability in various applications. However, the limit of detection of this technique is high for some elements compared to other techniques (e.g. ICP). Thus, the objective of this work is to improve the sensitivity of LIBS on the single pulse configuration, through integration with the laser-induced fluorescence (LIF) technique. This is done adding a laser with a wavelength in a resonant transition of the element whose emission intensity needs to be improved, focusing on reducing the matrix effects of samples. To achieve this purpose, a continuous external cavity diode laser was developed and its control driver, aiming to create a robust system, stable in frequency, with low spectral noise and resistant to adverse mechanical, electrical and thermal stresses. Both were integrated with a LIBS system for the evaluation of the LIBS-LIF technique efficiency.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.