• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Disertación de Maestría
DOI
https://doi.org/10.11606/D.18.2007.tde-06122007-155730
Documento
Autor
Nombre completo
Valéria Paula Venturini
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2007
Director
Tribunal
Pinotti Junior, Mario (Presidente)
Brandão, Dennis
Moraes, Cicero Couto de
Título en portugués
Desenvolvimento de um mestre PROFIBUS com a finalidade de análise de desempenho
Resumen en portugués
Quando se dispõe de um sistema de controle distribuído em tempo real, o atendimento aos requisitos temporais constitui-se num fator crucial para a aplicação. Assim, para garantir que tais requisitos sejam atendidos, é fundamental que o tráfego de mensagens no barramento seja gerenciado e controlado apropriadamente, evitando-se atrasos na comunicação para não prejudicar a performance do sistema e do produto final. Este trabalho apresenta um mestre PROFIBUS desenvolvido em PC, cujas finalidades foram analisar por meio de dados experimentais, a influência do parâmetro TTR no tempo de atualização das variáveis de processo no sistema e o tempo de reintegração da estação-mestre no anel lógico após perda de mensagem de token.
Título en inglés
Development of a PROFIBUS master for performance analyzing purpose
Palabras clave en inglés
Industrial automation
Network
Performance
PROFIBUS
Real-time distributed control
Resumen en inglés
Using a real-time distributed control system, it is crucial to fullfill the time requirements for an application. Therefore, to guarantee that these requirements are fulfilled, it is essential to manage and control the message traffic in the bus properly, avoiding delays in the communication that could compromise the final product and the system performance. This study presents a PROFIBUS master based on PC. The main purpose of the PROFIBUS master is to analyze, using empirical data, the influence of the TTR parameter in the updating time of the process variables and the time interval to reintegrate a master device to the logical ring after a token message is lost.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2007-12-10
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.