Mémoire de Maîtrise
DOI
https://doi.org/10.11606/D.18.2013.tde-02102013-164801
Document
Auteur
Nom complet
Ana Carolina Barbosa Faria Gonçalves
Unité de l'USP
Domain de Connaissance
Date de Soutenance
Editeur
São Carlos, 2013
Directeur
Jury
Siqueira, Adriano Almeida Gonçalves (Président)
Goroso, Daniel Gustavo
Silva, Orivaldo Lopes da
Titre en portugais
Análise da usabilidade de um dispositivo robótico desenvolvido para reabilitação de tornozelo em indivíduos hemiparéticos pós acidente vascular encefálico
Mots-clés en portugais
Hemiparesia
Reabilitação do tornozelo
Reabilitação robótica
Resumé en portugais
As doenças cerebrovasculares, incluindo o acidente vascular encefálico (AVE), são a segunda causa de morte no mundo, e o principal causador das incapacidades na população adulta. Devido à reorganização cortical, quanto mais precoce a reabilitação é realizada, melhores são os resultados. Desta forma, novos tratamentos e soluções tecnológicas foram desenvolvidos para enfrentar os desafios da reabilitação pós AVE, por exemplo, aumento da intensidade e duração da terapia incluindo manipulação externa, treinamento do movimento bilateral, e reabilitação robótica. Os dispositivos robóticos possibilitam a realização de tarefas específicas repetidas vezes, de forma controlada e confiável, fator determinante para a facilitação da reorganização cortical, com aumento da habilidade motora e melhora do desempenho das atividades funcionais. O objetivo principal deste trabalho foi verificar a adequação e usabilidade da Plataforma Robótica de Reabilitação de Tornozelo - PRRT em indivíduos que precisam de reabilitação de tornozelo decorrente de sequela de AVE, a fim de realizar eventuais ajustes antes que o equipamento seja incorporado na prática clínica. A metodologia consistiu em verificar a adequação ergonômica e técnica do equipamento, e avaliar a satisfação do usuário após o seu uso por meio de questionário. O aparelho foi avaliado tanto em pacientes com déficit motor de hemiparesia, como em indivíduos sem deficiências. Os resultados experimentais mostram que o equipamento é adequado como um recurso auxiliar na avaliação da amplitude de movimento articular do tornozelo e da força muscular, beneficiando os terapeutas na avaliação dos ganhos reais obtidos com as terapias. A partir das respostas ao questionário, verifica-se que os indivíduos sentiram-se satisfeitos com o recurso. Portanto, conclui-se que a PRRT é um recurso auxiliar promissor no tratamento do tornozelo de indivíduos que sofreram lesão neurológica, podendo trazer benefícios em relação à amplitude de movimento e ganho de força, além de proporcionar uma terapia prazerosa e estimulante aos pacientes.
Titre en anglais
Usability analysis of a robotic device developed for ankle rehabilitation of post-stroke hemiparetic subjects
Mots-clés en anglais
Ankle rehabilitation
Hemiparesis
Rehabilitation robotics
Resumé en anglais
Cerebrovascular diseases, including stroke, are the second leading cause of death worldwide and the leading cause of disability in the adult population. Due to cortical reorganization, the earlier rehabilitation is performed, the better the results. In this way, new treatments and technological solutions were developed to meet the challenges of rehabilitation after stroke, for example, increase of intensity and duration of therapy including external manipulation, bilateral movement training, and rehabilitation robotics. Robotic devices allow performing specific tasks repeatedly in a controlled and reliable way, a key factor for cortical reorganization, with increase of motor skills and improvement of functional activities performance. The main objective of this work was to verify the adequacy and usability of the Robotic Platform for Ankle Rehabilitation in post-stroke patients who need ankle rehabilitation, in order to make any necessary adjustments before the equipment be incorporated into clinical practice. The methodology consisted in verifying ergonomic and technical adequacy, and evaluates user satisfaction after use through a questionnaire. The device was evaluated in patients with motor deficit of hemiparesis, as well as in individuals without disabilities. Experimental results show the proposed equipment is suitable as an auxiliary resource in evaluating the range of motion and muscle strength of the ankle, assisting therapists in the evaluation of real gains obtained with the therapies. From the questionnaire responses, the individuals said they were satisfied with the resource. Therefore, it is concluded that the PRRT is a promising auxiliary resource in the treatment of individuals who have suffered neurological damage, bringing benefits with relation to range of motion and muscle strength, as well as providing pleasurable and stimulating therapy to patients.
 
AVERTISSEMENT - Regarde ce document est soumise à votre acceptation des conditions d'utilisation suivantes:
Ce document est uniquement à des fins privées pour la recherche et l'enseignement. Reproduction à des fins commerciales est interdite. Cette droits couvrent l'ensemble des données sur ce document ainsi que son contenu. Toute utilisation ou de copie de ce document, en totalité ou en partie, doit inclure le nom de l'auteur.