Doctoral Thesis
DOI
https://doi.org/10.11606/T.18.2011.tde-07072011-172456
Document
Author
Full name
Osiris Cárdenas
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2011
Supervisor
Committee
Pagliuso, Josmar Davilson (President)
Fontes, Sergio Rodrigues
Sánchez, Caio Glauco
Santos, Antonio Moreira dos
Sogabe, Milton Norio
Title in Portuguese
Estudo comparativo da combustão de sebo bovino e diesel em fornalha calorimétrica flamotubular
Keywords in Portuguese
Combustíveis alternativos
Emissões poluentes
Queimador
Sebo
Transferência de calor
Abstract in Portuguese
Neste trabalho, avaliou-se a queima do sebo bovino por meio de uma fornalha calorimétrica flamotubular instrumentada que opera à pressão atmosférica. Como parte do trabalho experimental, foram analisadas as curvas de rendimento térmico da queima do combustível, sebo bovino, e verificou-se seu comportamento quanto à transferência de calor e emissão de gases. Experimentalmente, a fornalha calorimétrica foi remodelada e adaptada para operar com sebo bovino, incorporando-se a esta um elemento de aquecimento prévio, trata-se de um queimador desenvolvido no NETeF possuindo um sistema de alimentação com aquecimento para o combustível, já que o sebo se encontra no estado sólido a temperatura ambiente. O queimador utilizado no experimento foi do tipo misto. Os resultados das medições do poder calorífico do sebo bovino mostraram-se altos: 39.985,5 kJ/kg (dados obtidos no laboratório do NETeF), fazendo com que o sebo se torne uma fonte menos poluente.
Title in English
Study of heat transfer in the flame tube furnace using beef tallow
Keywords in English
'CO IND.2' emissions
Alternatives fuels
Burner
Heat transfer
Tallow
Abstract in English
In this study, we evaluated the burning of tallow by a calorimetric flamotubular instrumented furnace which operates at atmospheric pressure. As part of the experimental work, the curves of thermal efficiency of fuel combustion (beef tallow) were analyzed, and it was possible to set their composition toward the transfer of heat and gas emissions. Experimentally, the calorimetric furnace was remodeled and adapted to operate with beef tallow by incorporating an element of this preheating, it is a burner developed in NETeF and it has a system to supply heating for fuel, as the tallow is solid at room temperature. The burner used in the experiment was of mixed type. The results of measurements of the calorific value of beef tallow were shown to be high: 39985.5 kJ/kg (data obtained in the laboratory of NETeF), causing the fat to become a viable source.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date