Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2009.tde-13012011-133713
Document
Author
Full name
Alessandro David Vieira
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2009
Supervisor
Committee
Di Giacomo, Benedito (President)
Marques, Alessandro
Paziani, Fabrício Tadeu
Title in Portuguese
Calibração indireta de máquina de medir por coordenadas utilizando esquadro mecânico de esferas
Keywords in Portuguese
Calibração indireta de erros
Esquadro mecânico de esferas
Máquina de medir por coordenadas
Abstract in Portuguese
Com o crescimento industrial e tecnológico nas últimas décadas, as indústrias passaram a oferecer produtos customizados, ou seja, desenvolvidos com tolerâncias geométricas cada vez mais apertadas e geometrias cada vez mais complexas. Com isso, as máquinas de medir por coordenadas (MMC) vêm tornando-se instrumentos essenciais no ambiente industrial. A MMC é extremamente versátil o que possibilita a medição das mais diversas características geométricas e dimensionais. Padrões para calibração de MMC foram sugeridos e colocados em uso através dos anos, com a finalidade de utilizá-los em testes de aceitação e verificação periódica dos erros e da incerteza de medição de MMC. Novos artefatos para a calibração indireta de MMC visam melhorar os procedimentos de calibração para uso em sistemas de compensação de erros. Diante do exposto acima, este trabalho tem como objetivo desenvolver um procedimento de calibração indireta de MMC com o esquadro de esferas aliado a um modelo reduzido de sintetização de erros (MRSE) para uso em um Sistema de Compensação de Erros. O procedimento possibilita maior rapidez na obtenção dos valores e comportamentos dos erros quando comparado com outros procedimentos de calibração indireta. O procedimento proposto tem como vantagem o uso de um esquadro de esferas para medir todos os termos das equações das componentes do erro volumétrico, nas direções X, Y e Z de uma MMC.
Title in English
Indirect calibration of a coordinate measuring machine using mechanical ball square
Keywords in English
Coordinate measuring machine
Indirect error calibration
Mechanical ball square
Abstract in English
With the technological and industrial growth in recent decades, the industries began to offer customized products, that is, products that fit individual specifications and often present increasingly tight tolerances and increasingly complex geometries. Therefore, the coordinate measuring machines (CMMs) have become an essential tool in the industrial environment. The CMM is very versatile since it allows the measurement of several geometric and dimensional features at once. Different standards for the calibration of CMMs were suggested and put into use through the years. This type of standard is traditionally used in acceptance tests and periodic verifications of the CMMs and in the evaluation of measurement uncertainties. New artifacts for indirect calibration of CMMs are proposed to allow the development of better procedures of error evaluation and compensation. Considering the above, this work aims to develop a procedure for indirect calibration of CMMs using a mechanical ball square combined with a reduced model of synthesis of Errors (MRSE). As a result, a compensation system for CMM errors is obtained. The procedure allows a faster evaluation of the values and behaviors of errors when compared with other indirect calibration procedures. Additionally, the proposed procedure has the advantage of using a single artifact to measure all the components of the volumetric error in the directions X, Y and Z of a CMM.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2013-11-29
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.