• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tese de Doutorado
DOI
https://doi.org/10.11606/T.18.2015.tde-12052015-084649
Documento
Autor
Nome completo
Lourdes Cristina de Albuquerque Haach
E-mail
Unidade da USP
Área do Conhecimento
Data de Defesa
Imprenta
São Carlos, 2015
Orientador
Banca examinadora
Fortulan, Carlos Alberto (Presidente)
Gaspar, Ana Maria Minarelli
Rigo, Eliana Cristina da Silva
Rollo, João Manuel Domingos de Almeida
Zavaglia, Cecília Amélia de Carvalho
Título em português
Corpos compósitos de poli(metacrilato de metila) com microfibra de biovidro e poros para reparo de defeitos ósseos
Palavras-chave em português
Biovidro 45S5®
Hidroxiapatita
Materiais biocompatíveis
PMMA
Substitutos ósseos
Resumo em português
Este trabalho está baseado no desenvolvimento do compósito poli(metacrilato de metila) (PMMA) microfibra de biovidro 45S5® (BV) com porosidade para aplicação direcionada a implantes ósseos. O PMMA é um material do tipo bioinerte amplamente utilizado na fabricação de implantes. O biovidro 45S5® é um biomaterial bioativo classe-A, que significa ser capaz de integração com tecidos moles e ósseos. O presente trabalho objetiva a conjugação das propriedades destes dois materiais em um conceito que introduz microfibra de biovidro 45S5® e porosidade em uma matriz de PMMA na busca de um material com elevada osteointegração e que permita a manufatura de implantes com adequada resistência a carregamentos mecânicos. Foram manufaturados e avaliados fisicamente e in vivo corpos de prova de PMMA com introdução de 20% de microfibra de biovidro (densos e porosos a 80%), corpos de PMMA com introdução de hidroxiapatita (densos e porosos a 80%) e de PMMA (densos e porosos a 80%) para controle. Foram realizados testes mecânicos de compressão e de flexão a três pontos para medidas de resistência e rigidez. Também foram realizadas medidas da microdureza Vickers e da densidade das amostras. Os resultados médios obtidos da tensão de escoamento e módulo elástico para os corpos de prova com introdução de 20% de microfibra de biovidro nos ensaios de compressão foram de 44 MPa e 1403 MPa respectivamente para as amostras densas e de 8 MPa e 13 MPa para as amostras porosas e nos ensaios de flexão foram de 48 MPa e 8129 MPa para os corpos densos e de 5 MPa e 97 MPa para os corpos porosos. A modelagem matemática a partir dos resultados permite a determinação antecipada da formulação para o atendimento específico de cada proposta de implante. Os implantes ensaiados in vivo com adição de microfibra de Biovidro 45S5® foram os que apresentaram os melhores resultados em integração óssea e controle da inflamação local.
Título em inglês
Composite samples of poly(methyl methacrylate) with bioglass microfiber and pores to repair bone defects
Palavras-chave em inglês
45S5® bioglass
Biocompatible materials
Bone substitutes
Hydroxyapatite
PMMA
Resumo em inglês
This work is based on the development of poly(methyl methacrylate) (PMMA) - bioglass 45S5® microfibers composite with porosity for bone implants application. PMMA is a bioinert material widely used in the manufacture of biological implants. The 45S5® bioglass is a bioactive class-A biomaterial which indicates ability to integrate with bone and soft tissues. The present study aims to combine the properties of these two materials on a concept that introduces bioglass 45S5® microfibers and porosity in a matrix of PMMA in order to find a material with high bone integration and capable of manufacture implants with adequate resistance to mechanical loads. Samples of PMMA with the introduction of 20% of bioglass microfiber (dense and 80% of porous), PMMA with introduction of hydroxyapatite (dense and 80% of porous), and PMMA (dense and 80% of porous) for control were fabricated and evaluated both physically and in vivo. Mechanical tests such as compression and three points bending have been performed for measurements of strain and stiffness. Measurements of Vickers microhardness and density of the samples also were performed. The average results of yield stress and elastic modulus for the samples with the introduction of 20% microfiber bioglass in compression tests were 44 MPa and 1403 MPa respectively for dense samples and 8 MPa and 13 MPa for porous samples and in bending tests were 48 MPa and 8129 MPa for dense bodies and 5 MPa and 97 MPa for the porous bodies. The mathematical modeling based on the results allows the early determination of the formulation to meet the specific needs of each implant proposal. The implants tested in vivo with addition of 45S5® bioglass microfiber presented the best results in bone integration and control of local inflammation when compared with all the other groups with the scaffold presence.
 
AVISO - A consulta a este documento fica condicionada na aceitação das seguintes condições de uso:
Este trabalho é somente para uso privado de atividades de pesquisa e ensino. Não é autorizada sua reprodução para quaisquer fins lucrativos. Esta reserva de direitos abrange a todos os dados do documento bem como seu conteúdo. Na utilização ou citação de partes do documento é obrigatório mencionar nome da pessoa autora do trabalho.
teseLourdesHaach.pdf (82.14 Mbytes)
Data de Publicação
2015-05-20
 
AVISO: Saiba o que são os trabalhos decorrentes clicando aqui.
Todos os direitos da tese/dissertação são de seus autores
CeTI-SC/STI
Biblioteca Digital de Teses e Dissertações da USP. Copyright © 2001-2024. Todos os direitos reservados.