Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2006.tde-08022007-105919
Document
Author
Full name
Luiz Carlos Corrêa
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2006
Supervisor
Committee
Corrêa, Nivaldo Aparecido (President)
Argondizo, Alexandre
Schulz, Harry Edmar
Title in Portuguese
Controle do processo da transferência de oxigênio em corpos hídricos
Keywords in Portuguese
Aeração
Controle PID
Identificação do processo
Oxigênio dissolvido
Transferência de oxigênio
Abstract in Portuguese
A presente proposta de estudo refere-se à identificação de modelo linear empírico para processo de transferência de oxigênio das bolhas de ar para o meio líquido, simulação para testes de controle e implementação de uma estratégia de controle em escala laboratorial em tempo real. Os ensaios de controle foram na unidade experimental (canal aberto) existente no laboratório de hidráulica ambiental o qual foi adaptado para aeração com sensores, atuadores, microcomputador, interface AD/DA. Foi testado o algoritmo de controle do tipo convencional PID (Proportional Integral Derivative control). Com os resultados obtidos da perturbação degrau na variável de entrada (alimentação do ar) foi possível identificar o sistema como um modelo de primeira ordem, suficiente para os propósitos de controle. Baseado na identificação, foi ajustado um controlador PID para implementação experimental. A principal contribuição desta pesquisa consistiu no emprego de uma estratégia de controle adequada na prática, ao processo de aeração.
Title in English
Control of oxygen transfer in water bodies
Keywords in English
Aeration
Dissolved oxygen
Oxygen transfer
PID control
Process identification
Abstract in English
The current study refers to the identification of an empirical linear model for the oxygen transfer process from air bubbles to liquid, control tests simulation and implementation of a control strategy at real time in laboratory scale. The control tests were carried out at the experimental unit (open channel) located at the environmental hydraulic laboratory which was adapted to aeration process with sensors, actuators, microcomputer, AD/DA interface. The classic PID (Proportional Integral Derivative control) algorithm was tested. With results from step response of input variable (air feeding) it was possible to identify the system as a first order model, enough for the control purposes. Based on the identification, a PID controller was adjusted for the experimental implementation. The main contribution of this work consisted of the employment of an appropriate control strategy to the aeration process in practice.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2007-03-13
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.