• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Tesis Doctoral
DOI
https://doi.org/10.11606/T.18.2007.tde-07042008-144334
Documento
Autor
Nombre completo
Juliana Berninger da Costa
Dirección Electrónica
Instituto/Escuela/Facultad
Área de Conocimiento
Fecha de Defensa
Publicación
São Carlos, 2007
Director
Tribunal
Espíndola, Evaldo Luiz Gaeta (Presidente)
Daniel, Luiz Antonio
Lombardi, Ana Teresa
Piveli, Roque Passos
Rocha, Odete
Título en portugués
Avaliação ecotoxicológica de efluente de tratamento secundário de esgoto sanitário após desinfecção com ácido peracético, cloro, ozônio e radiação ultravioleta
Palabras clave en portugués
Ácido peracético
Cloro
Desinfecção
Ozônio
Radiação ultravioleta
Toxicidade
Resumen en portugués
Neste estudo foi avaliado o potencial tóxico de diferentes desinfetantes (cloro, ácido peracético, radiação ultravioleta e ozônio) utilizados na desinfecção de esgotos sanitários. Para tanto, foram realizados ensaios de desinfecção (em diversas concentrações e tempos de contato) com o esgoto doméstico originário da estação de tratamento de esgotos da cidade de Araraquara (SP) e, posteriormente, ensaios de toxicidade a fim de verificar possíveis efeitos agudos e crônicos nos seguintes organismos-teste: Daphnia similis, Ceriodaphnia silvestrii, Chironomus xanthus, Danio rerio e Allium cepa. Todos os desinfetantes, nas condições experimentais testadas, foram capazes de produzir efeitos deletérios aos organismos-teste utilizados nesta pesquisa. O cloro foi considerado o desinfetante mais tóxico, sendo seguido pelo ozônio, ácido peracético e radiação UV. Verificou-se ainda que quando o efluente não desinfetado foi tóxico aos organismos-alvo, sua toxidez foi potencializada com a adição dos diferentes agentes desinfetantes. Os resultados obtidos neste estudo sugerem que a utilização do cloro para desinfecção de esgotos sanitários, sem prévia descloração, deve ser revista, em face da eficiência satisfatória de inativação de bactérias proporcionada por outros agentes de desinfecção potencialmente menos tóxicos (tais como o ácido peracético e a radiação UV).
Título en inglés
Ecotoxicological evaluation of wastewater secondary effluent disinfected with peracetic acid, chlorine, ozone and ultraviolet radiation
Palabras clave en inglés
Chlorine
Disinfection
Ozone
Peracetic acid
Toxicity
Ultraviolet radiation
Resumen en inglés
In this study, it was evaluated the toxic potential of different disinfectant agents (chlorine, peracetic acid, ultraviolet radiation and ozone) used in the disinfection of urban wastewater. For so much, disinfection assays were accomplished (in several concentrations and contact times) with the domestic sewage from Araraquara city (SP) and toxicity bioassays were developed in order to verify possible acute and chronic effects in the following test-organisms: Daphnia similis, Ceriodaphnia silvestrii, Chironomus xanthus, Danio rerio and Allium cepa. All the disinfectants, in the tested experimental conditions, were capable to produce harmful effects to the test-organisms used in this research. Chlorine was considered the most toxic disinfectant, being followed by ozone, peracetic acid and UV radiation. It was noticed that when the effluent, by itself, was toxic to the test-organism, its toxicity was increased with the different disinfecting agents' addition. The results obtained in this study suggest that the use of chlorine as a wastewater disinfectant, without previous dechlorination, should be reviewed, because it was observed that other disinfection agents (such as peracetic acid and UV radiation) were able to promote satisfactory levels of bacteria inactivation for potentially less toxicity.
 
ADVERTENCIA - La consulta de este documento queda condicionada a la aceptación de las siguientes condiciones de uso:
Este documento es únicamente para usos privados enmarcados en actividades de investigación y docencia. No se autoriza su reproducción con finalidades de lucro. Esta reserva de derechos afecta tanto los datos del documento como a sus contenidos. En la utilización o cita de partes del documento es obligado indicar el nombre de la persona autora.
Fecha de Publicación
2008-04-09
 
ADVERTENCIA: Aprenda que son los trabajos derivados haciendo clic aquí.
Todos los derechos de la tesis/disertación pertenecen a los autores
CeTI-SC/STI
Biblioteca Digital de Tesis y Disertaciones de la USP. Copyright © 2001-2024. Todos los derechos reservados.