• JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
  • JoomlaWorks Simple Image Rotator
 
  Bookmark and Share
 
 
Master's Dissertation
DOI
https://doi.org/10.11606/D.18.2012.tde-30082012-112336
Document
Author
Full name
Luciano do Valle Monteiro
E-mail
Institute/School/College
Knowledge Area
Date of Defense
Published
São Carlos, 2012
Supervisor
Committee
Povinelli, Jurandyr (President)
Daniel, Luiz Antonio
Lanza, Marcos Roberto de Vasconcelos
Title in Portuguese
Estudo da tratabilidade do lixiviado de aterro sanitário pelos processos oxidativos avançados foto-Fenton, ozônio e ozônio combinado com peróxido de hidrogênio
Keywords in Portuguese
"Air-stripping"
Foto-Fenton
Lixiviado de aterro sanitário
Ozônio
Peróxido de hidrogênio
Processo oxidativo avançado
Abstract in Portuguese
O lixiviado de aterro sanitário possui constituição complexa e é altamente poluente. Neste contexto, os processos oxidativos avançados se destacam como pré-tratamento, objetivando a remoção ou diminuição da recalcitrância do lixiviado. Neste trabalho foram utilizados os Processos Oxidativos Avançados (POAs) foto-Fenton, ozônio e ozônio combinado com peróxido de hidrogênio. Avaliou-se a influência do pré-tratamento por air-stripping, a variação na produção de ozônio em 80 e 100%, a melhor dose de peróxido de hidrogênio correspondente a 20, 40 e 80% da dose de 6g O3/L empregada nos tratamentos com ozônio, a remoção de matéria orgânica, nitrogênio amoniacal total (NAT), alcalinidade, sólidos dissolvidos totais (SDT) (cloretos), produção de nitrito e nitrato, melhor razão molar [H2O2]/[Fe2+] para o tempo de contato de 80 min no foto-Fenton, uso do número médio de oxidação do carbono (NMOC) e a quantificação do ácido oxálico formado após a aplicação dos POAs. O tratamento por O3/H2O2 (1,2 g H2O2/L e produção de O3 em 80%) obteve a maior remoção de matéria orgânica, 0,14 g massa removida de Carbono Orgânico Total (COT) / massa consumida de O3 e 0,43 g/g para a Demanda Química de Oxigênio (DQO). Quanto ao foto-Fenton, averiguou-se o máximo de 74% remoção de COT e 65% remoção DQO para a razão molar [H2O2]/[Fe2+] igual a 2. Também se notou formação de sólidos sedimentáveis neste processo aplicado ao lixiviado bruto. O pré-tratamento por air-stripping não promoveu incremento na remoção de matéria orgânica. As concentrações de NAT, alcalinidade, SDT (cloretos) se mantiveram elevadas após a aplicação dos POA. Ocorreu formação de nitrato em todos os tratamentos. O uso do NMOC foi adequado e demonstrou ocorrência de oxidação nos processos. A quantificação do ácido oxálico formado após a aplicação dos POAs não foi apropriada nesta pesquisa.
Title in English
Study of treatability of landfill leachate by advanced oxidation processes photo-Fenton, ozone and ozone combined with hydrogen peroxide
Keywords in English
"Air-stripping"
Advanced oxidation process
Hydrogen peroxide
Ozone
Photo-Fenton
Sanitary landfill leachate
Abstract in English
The landfill leachate is a major waste produced by the landfill and its constitution complex and highly polluting motivate research in order to adapt their disposal on the environment. In this context, the advanced oxidation processes stand out as a pretreatment, in order to remove or decrease the recalcitrance of the leachate. In this work we used the photo-Fenton AOPs, ozone and ozone combined with hydrogen peroxide. We evaluated the effect of pretreatment for air-stripping, the variation in the production of ozone 80 and 100%, the best dose of hydrogen peroxide equal to 20, 40 and 80% of the dose of 6g O3/ L used in the treatments with ozone, the removal of organic matter, total ammonia nitrogen, alkalinity, dissolved solids (chlorides), production of nitrite and nitrate, best molar ratio [H2O2]/[Fe2+] to the contact time of 80 min in the photo-Fenton, average number of carbon oxidation use and the measurement of oxalic acid formed after application of the AOPs. The AOP O3/H2O2 (1.2g H2O2/L and O3 production by 80%) had the highest removal of organic matter, 0.14 g of TOC removed mass/ mass consumed O3 and 0.43 g/g for COD. As for the photo-Fenton, it was found a maximum of 74% removal of TOC and 65% for COD removal molar ratio [H2O2]/[Fe2+] equal to 2. It was also noted the formation of settle able solids in the process applied to the raw leachate. Pretreatment by air-stripping did not promote an increase in organic matter removal. Total ammonia nitrogen concentrations, alkalinity, dissolved solids (chlorides) remained high after application of the AOP, indicating possible oxidant demand. For nitrate formation occurred in all treatments, while only the photo-Fenton was no formation of nitrite. The use of average number of carbon oxidation was adequate and showed occurrence of oxidation processes. The quantification of oxalic acid formed after the application of AOPs was not appropriate in this research.
 
WARNING - Viewing this document is conditioned on your acceptance of the following terms of use:
This document is only for private use for research and teaching activities. Reproduction for commercial use is forbidden. This rights cover the whole data about this document as well as its contents. Any uses or copies of this document in whole or in part must include the author's name.
Publishing Date
2014-09-09
 
WARNING: Learn what derived works are clicking here.
All rights of the thesis/dissertation are from the authors
CeTI-SC/STI
Digital Library of Theses and Dissertations of USP. Copyright © 2001-2024. All rights reserved.